Implementation of Multi-Curie Production of (99m)Tc by Conventional Medical Cyclotrons.

نویسندگان

  • François Bénard
  • Kenneth R Buckley
  • Thomas J Ruth
  • Stefan K Zeisler
  • Julius Klug
  • Victoire Hanemaayer
  • Milan Vuckovic
  • Xinchi Hou
  • Anna Celler
  • Jean-Pierre Appiah
  • John Valliant
  • Michael S Kovacs
  • Paul Schaffer
چکیده

UNLABELLED (99m)Tc is currently produced by an aging fleet of nuclear reactors, which require enriched uranium and generate nuclear waste. We report the development of a comprehensive solution to produce (99m)Tc in sufficient quantities to supply a large urban area using a single medical cyclotron. METHODS A new target system was designed for (99m)Tc production. Target plates made of tantalum were coated with a layer of (100)Mo by electrophoretic deposition followed by high-temperature sintering. The targets were irradiated with 18-MeV protons for up to 6 h, using a medical cyclotron. The targets were automatically retrieved and dissolved in 30% H2O2. (99m)Tc was purified by solid-phase extraction or biphasic exchange chromatography. RESULTS Between 1.04 and 1.5 g of (100)Mo were deposited on the tantalum plates. After high-temperature sintering, the (100)Mo formed a hard, adherent layer that bonded well with the backing surface. The targets were irradiated for 1-6.9 h at 20-240 μA of proton beam current, producing up to 348 GBq (9.4 Ci) of (99m)Tc. The resulting pertechnetate passed all standard quality control procedures and could be used to reconstitute typical anionic, cationic, and neutral technetium radiopharmaceutical kits. CONCLUSION The direct production of (99m)Tc via proton bombardment of (100)Mo can be practically achieved in high yields using conventional medical cyclotrons. With some modifications of existing cyclotron infrastructure, this approach can be used to implement a decentralized medical isotope production model. This method eliminates the need for enriched uranium and the radioactive waste associated with the processing of uranium targets.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Direct Technetium radiopharmaceuticals production using a 30MeV Cyclotron

BACKGROUND AND THE PURPOSE OF THE STUDY Technetium-99m is the major radionuclide used in the world and mainly is provided by fission product. However extensive research has been conducted on the use of accelerators for production of (99m)Tc. This investigation reports the production of (99m)Tc radioisotope using cyclotrons and the preparation, quality control and biodistribution studies of four...

متن کامل

Feasibility studies towards future self-sufficient supply of the 99Mo-99mTc isotopes with Japanese accelerators

In order to establish a self-sufficient supply of (99m)Tc, we studied feasibilities to produce its parent nucleus, (99)Mo, using Japanese accelerators. The daughter nucleus, (99m)Tc, is indispensable for medical diagnosis. (99)Mo has so far been imported from abroad, which is separated from fission products generated in nuclear reactors using enriched (235)U fuel. We investigated (99m)Tc produc...

متن کامل

Comparison of Tc-99m Ethylenedicysteine (Tc-99m EC) with Tc-99m DPTA in evaluation of renal disease [Persian]

Tc-99m-EC is a new renal radiopharmaceutical introduced as an alternative for Tc-99m MAG3. Twenty-three normal volunteers and patients in different .stages of renal disease were evaluated with Te-99m EC and Tc-99m DTPA. The mean initial uptake of EC was significantly higher as compared to DTPA. There was a high correlation between rectangular and hand-drawn ROls for kidney and background,...

متن کامل

Comparative assessment of renal Tc-99m DMSA scan and renal sonography findings in complication of urinary tract infections [Persian]

Urinary tract infection (UTI) is a common disease in childhood specially in female. In this study 50 patients with stablished diagnosis of UTI were evaluated by both renal scan with Tc-99m DMSA and renal sonography. The study revealed that most urinary tract infections are in children, Female sex between 5-9 years of age. Therefore the most important complications (Renal scarring) are als...

متن کامل

Body outlining using Tc-99m filled flood source for lymphoscintigraphy imaging

  Introduction: In the current study, we evaluated the feasibility of body outlining using Tc-99m filled flood source for lymphoscintigraphy imaging. Methods: 80 patients were included in the study. Sentinel node mapping was done using Tc-99m Antimony sulfide colloid. For outlining the body a Tc-99m filled flood source was used which was placed behind or lateral to t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 55 6  شماره 

صفحات  -

تاریخ انتشار 2014