Widely-Tunable Rapid-Scanning Mid-IR Laser Spectrometer for Industrial Gas Process Stream Analysis
نویسندگان
چکیده
We demonstrate selective detection of hydrocarbons using a widely-tunable, rapidlyswept, high-resolution spectrometer based on a mid-infrared laser source using differencefrequency generation in periodically poled lithium niobate waveguides. ©2006 Optical Society of America OCIS codes: (120.6200) Spectrometers and spectroscopic instrumentation General; (190.2620) Frequency conversion Rapid, non-intrusive sensors for small hydrocarbon molecules are needed by the petrochemical industry to monitor the concentrations of multiple species in its process streams, so that the yield of the desired end products can be optimized. We report the spectroscopic detection of methane, ethylene, and propylene using a sensor which is capable of meeting industry requirements for selectivity, sensitivity, speed, and compactness. This instrument could be used to detect a wide variety of small molecules containing carbon-hydrogen bonds. The sensor is a laser spectrometer based on difference-frequency generation (DFG) in periodically poled lithium niobate (PPLN) waveguides. Waveguide DFG has been shown to be an effective method of generating tunable midinfrared radiation for a variety of gas-sensing applications [1]. The tuning range of such a laser source is limited by the phase-matching properties of PPLN. Recently we have shown that broad phase-matching resonances for midinfrared generation in waveguide DFG can be observed when the wavelengths of the interacting lasers are properly chosen [2]. This work is built upon the DFG experiments of Goldberg et al., who observed broad phase-matching resonances in bulk DFG [3]. In the present work, a tuning range of >400 cm is demonstrated using a new waveguide device which allows a telecommunications laser, engineered for rapid wavelength sweeps, to be used as the tuning element. The tuning speed and linearity of the swept-wavelength laser determine the instrument’s speed and spectral accuracy, and, since both lasers are narrow-linewidth, the spectral resolution is limited only by the laser linewidths and limits on the data acquisition rate. In terms of speed and resolution, this spectrometer rivals the performance of high-resolution FTIR instruments. The mid-IR spectrometer is shown in Figure 1. This system is based on difference frequency generation (DFG) in a PPLN channel waveguide with an 18.5 mm long mixing region, utilizing a 931 nm fixed-wavelength pump laser (Sacher Lasertechnik Lynx series, ~50mW when fiber-coupled) which is mixed with a tunable, swept-wavelength signal laser tunable between 1263 nm and 1343 nm (Thorlabs/Radians Innova INTUN –T series ~6mW when fibercoupled). The fiber-coupled outputs of the lasers are combined in a fiber-optic coupler (Canadian Instrumentation & Research Ltd., using 980-nm PM fiber), and the output fiber ferrule is butt-coupled and epoxied to the PPLN waveguide. All fibers are PM to preserve the polarization necessary for proper guiding in the waveguide and the connectors are APC to eliminate etalons. To achieve proper phase-matching, the PPLN chip is heated to 65°C and the resulting mid-IR light is focused by a ZnSe lens and filtered by a broadband mid-IR pass filter. The light is then chopped at ~4kHz, split into signal and reference beams by a ZnSe beamsplitter and detected using a pair of thermoelectrically cooled InAs detectors. The signal beam passes through a gas cell with wedged, anti-reflection coated ZnSe windows allowing differential absorption measurements. Ratiometric detection is used to eliminate etalon effects from the tunable laser, PPLN chip and other optics and to account for laser power and wavelengthdependent coupling efficiency variations. The signals from the detectors are sent to two lockin amplifiers and the resulting voltage signals are detected by a fast data acquisition (DAQ) board. The DAQ board is also used to send a swept analog signal to the tunable laser for tuning. The acquisition speed and accuracy of the obtained spectra are predicated on the tuning characteristics of the analog swept-wavelength laser which is, by design, highly linear and highly repeatable and can be tuned at speeds up to 100nm/s. The linearity of the scan is further improved by pre-compensating the analog waveform for any linearity variations (which can be measured by scanning the laser over a known etalon and accounting for any observed linearity errors) and using this corrected waveform when scanning the laser. A program written in LabVIEW controls the coordinated laser scanning, linearity calibration and simultaneous data acquisition. The minimum achievable linewidth for the spectrometer, determined by the convolved lineshape functions of the pump and signal lasers, is ~120 MHz. In practice, the linewidth is larger than this because of limitations imposed by the finite DAQ rate. For example, a typical measurement scanning the entire tuning range of the instrument in 1300 nm Tunable Laser 931 nm Fixed Laser Computer DAQ Card Lockin Amp. 1
منابع مشابه
Widely tunable rapid-scanning mid-infrared laser spectrometer for industrial gas process stream analysis.
A mid-infrared spectrometer with a tuning range of >400 cm(-1) in the C-H stretching region of the spectrum has been designed and constructed. The spectrometer is based on the difference-frequency generation of two tunable diode lasers in periodically poled lithium niobate waveguides. Tuning is achieved by varying a single parameter, the wavelength of one of the near-infrared input lasers. The ...
متن کاملMonolithically, widely tunable quantum cascade lasers based on a heterogeneous active region design
Quantum cascade lasers (QCLs) have become important laser sources for accessing the mid-infrared (mid-IR) spectral range, achieving watt-level continuous wave operation in a compact package at room temperature. However, up to now, wavelength tuning, which is desirable for most applications, has relied on external cavity feedback or exhibited a limited monolithic tuning range. Here we demonstrat...
متن کاملDevelopment of a tunable mid-IR difference frequency laser source for highly sensitive airborne trace gas detection.
The development of a compact tunable mid-IR laser system at 3.5 micrometers for quantitative airborne spectroscopic trace gas absorption measurements is reported. The mid-IR laser system is based on difference frequency generation (DFG) in periodically poled LiNbO3 and utilizes optical fiber amplified near-IR diode and fiber lasers as pump sources operating at 1083 nm and 1562 nm, respectively....
متن کاملWidely Tunable Monolithic Mid-Infrared Quantum Cascade Lasers Using Super-Structure Grating Reflectors
A monolithic, three-section, and widely tunable mid-infrared (mid-IR) quantum cascade laser (QCL) is demonstrated. This electrically tuned laser consists of a gain section placed between two super structure grating (SSG) distributed Bragg reflectors (DBRs). By varying the injection currents to the two grating sections of this device, its emission wavelength can be tuned from 4.58 μm to 4.77 μm ...
متن کاملOn-line monitoring of methanol and methyl formate in the exhaust gas of an industrial formaldehyde production plant by a mid-IR gas sensor based on tunable Fabry-Pérot filter technology
On-line monitoring of key chemicals in an industrial production plant ensures economic operation, guarantees the desired product quality, and provides additional in-depth information on the involved chemical processes. For that purpose, rapid, rugged, and flexible measurement systems at reasonable cost are required. Here, we present the application of a flexible mid-IR filtometer for industrial...
متن کامل