Comparison of SAPIEN 3 and SAPIEN XT transcatheter heart valve stent-frame expansion: evaluation using multi-slice computed tomography

نویسندگان

  • Yoshio Kazuno
  • Yoshio Maeno
  • Hiroyuki Kawamori
  • Nobuyuki Takahashi
  • Yigal Abramowitz
  • Hariri Babak
  • Mohammad Kashif
  • Tarun Chakravarty
  • Mamoo Nakamura
  • Wen Cheng
  • John Friedman
  • Daniel Berman
  • Raj R. Makkar
  • Hasan Jilaihawi
چکیده

AIMS Stent-frame morphology of the newer-generation, balloon-expandable transcatheter heart valve (THV), the SAPIEN 3 (S3), after transcatheter aortic valve implantation (TAVI) is unknown. We evaluated the THV stent-frame morphology post TAVI of the S3 using multi-slice computed tomography (MSCT) compared with the prior-generation THV, SAPIEN XT (S-XT). METHODS AND RESULTS A total of 94 consecutive participants of RESOLVE registry (NCT02318342) had MSCT after balloon-expandable TAVI (S3 = 39 and S-XT = 55). The morphology of the THV stent-frame was evaluated for expansion area and eccentricity at the THV-inflow, native annulus, mid-THV and THV-outflow levels. Mean %-expansion area for the S3 and the S-XT was 100.9 ± 5.7 and 96.1 ± 5.5%, respectively (P < 0.001). In the S3 group, the THV-inflow level had the largest value of %-expansion area, which decreased from THV-inflow to mid-THV level (105.2 ± 6.4 to 96.5 ± 5.9%, P < 0.001). However, in the S-XT group, %-expansion area increased from THV-inflow level to mid-THV level (93.2 ± 6.2 to 95.1 ± 6.1%, P = 0.0058). On nominal delivery balloon volume, the S3 in 88.5% of cases had overexpansion at the THV-inflow level. The observed degree of THV oversizing of the S3 was significantly lower than the S-XT (6.3 ± 8.6 vs. 11.8 ± 8.5%, P = 0.0027). Nonetheless, the incidence of post-procedural paravalvular aortic regurgitation (PVR) ≥ mild following the S3 TAVI was also significantly lower than the S-XT TAVI (17.9 vs. 43.6%, P = 0.014). CONCLUSION The newer-generation, balloon-expandable device, the S3, has a flared inflow morphology, whereas the prior-generation device, the S-XT, has relatively constrained inflow morphology post TAVI. This may contribute to a lesser degree of PVR with the S3.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Structural integrity of balloon-expandable stents after transcatheter aortic valve replacement: assessment by multidetector computed tomography.

OBJECTIVES This study sought to evaluate the structural integrity of balloon-expandable stents used in transcatheter aortic valve replacement. BACKGROUND Underexpansion, deformation, or fracture of stent frames may affect transcatheter heart valve (THV) function and durability. METHODS Patients >1 year after transcatheter aortic valve replacement underwent multidetector computed tomography....

متن کامل

Comparison of acute elastic recoil between the SAPIEN-XT and SAPIEN valves in transfemoral-transcatheter aortic valve replacement.

BACKGROUND The SAPIEN-XT is a newer generation balloon-expandable valve created of cobalt chromium frame, as opposed to the stainless steel frame used in the older generation SAPIEN valve. We sought to determine if there was difference in acute recoil between the two valves. METHODS All patients who underwent transfemoral-transcatheter aortic valve replacement using the SAPIEN-XT valve at the...

متن کامل

Overexpansion of the SAPIEN 3 Transcatheter Heart Valve: A Feasibility Study.

Computed tomography (CT) images with cross-sectional areas of overex Lifesciences), 23-, 26-, and a 29-mm SAPIEN 3 transcatheter heart valv several new features designed to address the limitations of earlier generation devices. An initial feasibility study performed in Europe and Canada using the SAPIEN 3 demonstrated excellent early outcomes with a 30-day mortality rate of 2.1%, a stroke rate ...

متن کامل

Comparison between the SAPIEN S3 and the SAPIEN XT transcatheter heart valves: A single-center experience

AIM To investigate the clinical outcomes of transcatheter aortic valve implantation (TAVI) with the SAPIEN 3 transcatheter heart valve (S3-THV) vs the SAPIEN XT valve (XT-THV). METHODS We retrospectively analyzed 507 patients that underwent TAVI with the XT-THV and 283 patients that received the S3-THV at our institution between March 2010 and December 2015. RESULTS Thirty-day mortality (3....

متن کامل

How to Adapt the Implantation Technique for the New SAPIEN 3 Transcatheter Heart Valve Design

The new balloon-expandable Edwards SAPIEN 3 THV has significant design improvements requiring adjustments in the implantation technique as compared to the previous generation SAPIEN XT. Basically, the new valve requires less oversizing due to the outer skirt, which, if positioned underneath the annulus, can reduce the occurrence and severity of paravalvular leak (PVL). As with any transcatheter...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2016