Right atrial septal electrode for reducing the atrial defibrillation threshold.

نویسندگان

  • X Zheng
  • M E Benser
  • G P Walcott
  • R E Ideker
چکیده

BACKGROUND The atrial defibrillation threshold (ADFT) energy of the standard lead configuration, right atrial appendage (RAA) to coronary sinus (CS), was reduced by >50% with the addition of a third electrode traversing the atrial septum in a previous study. This study determined whether the ADFT would be lowered by a more clinically practical third electrode placed in the right atrium along the atrial septum (RSP). METHODS AND RESULTS Sustained atrial fibrillation was induced in 8 closed-chest sheep with burst pacing and maintained with pericardial infusion of acetyl-beta-methylcholine chloride. A custom-made, dual-defibrillation catheter was placed with electrodes in the lateral RA, CS, and RSP. A separate defibrillation catheter was also placed in the RAA. ADFT characteristics of RAA-->CS and 6 other single- or sequential-shock configurations were determined in random order by using biphasic, truncated-exponential waveforms in a multiple-reversal protocol. The delivered-energy, peak-voltage, and peak-current ADFTs for the sequential-shock configuration CS-->RSP/RA-->RSP (0.53+/-0.31 J, 86+/-22 V, and 1.6+/-0.6 A, respectively) were significantly lower than those of RAA-->CS (1.14+/-0.64 J, 157+/-34 V, and 2.5+/-1.1 A, respectively). The ADFT characteristics of RAA-->CS and RA-->CS were not significantly different, nor were those of CS-->RSP/RA-->RSP and CS-->RSP/RAA--> RSP. CONCLUSIONS The ADFT of the standard RAA-->CS configuration may be markedly reduced with an additional electrode situated at the RSP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reduction of atrial defibrillation threshold with an interatrial septal electrode.

BACKGROUND The standard lead configuration for internal atrial defibrillation consists of a shock between electrodes in the right atrial appendage (RAA) and coronary sinus (CS). We tested the hypothesis that the atrial defibrillation threshold (ADFT) of this RAA-->CS configuration would be lowered with use of an additional electrode at the atrial septum (SP). METHODS AND RESULTS Sustained atr...

متن کامل

Implantable atrial defibrillator with a single-pass dual-electrode lead.

OBJECTIVES We examined the feasibility and efficacy of using a single-pass, dual-electrode (Solo) lead for atrial fibrillation (AF) detection and defibrillation. BACKGROUND The efficacy and safety of an implantable atrial defibrillator (IAD) has been extensively studied; however, separate right atrial (RA) and coronary sinus (CS) defibrillation leads are used for the present system. METHODS...

متن کامل

Atrial defibrillation with a transvenous lead: a randomized comparison of active can shocking pathways.

OBJECTIVES The purpose of this study was to compare transvenous atrial defibrillation thresholds with lead configurations consisting of an active left pectoral electrode and either single or dual transvenous coils. BACKGROUND Low atrial defibrillation thresholds are achieved using complex lead systems including coils in the coronary sinus. However, the efficacy of more simple ventricular defi...

متن کامل

Comparison of the defibrillation threshold and the upper limit of ventricular vulnerability.

To examine the relationship between the defibrillation threshold and the strength of shocks that induce ventricular fibrillation during the vulnerable period, we determined the defibrillation threshold in 22 open-chest dogs using epicardial defibrillation electrodes with the cathode at the ventricular apex and the anode at the right atrium. We also determined whether there was an upper limit of...

متن کامل

Marked reduction in atrial defibrillation thresholds with repeated internal cardioversion.

OBJECTIVES This study was performed to assess the atrial defibrillation threshold in patients with recurrent atrial fibrillation (AF) using repeated internal cardioversion. BACKGROUND Previous studies in patients with chronic AF undergoing internal cardioversion have shown this method to be effective and safe. However, current energy requirements might preclude patients with longer-lasting AF...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 104 9  شماره 

صفحات  -

تاریخ انتشار 2001