Multiphase hemodynamic simulation of pulsatile flow in a coronary artery.
نویسندگان
چکیده
A multiphase transient non-Newtonian three-dimensional (3-D) computational fluid dynamics (CFD) simulation has been performed for pulsatile hemodynamics in an idealized curved section of a human coronary artery. We present the first prediction, to the authors' knowledge, of particulate buildup on the inside curvature using the multiphase theory of dense suspension hemodynamics. In this study, the particulates are red blood cells (RBCs). The location of RBC buildup on the inside curvature correlates with lower wall shear stress (WSS) relative to the outside curvature. These predictions provide insight into how blood-borne particulates interact with artery walls and hence, have relevance for understanding atherogenesis since clinical observations show that atherosclerotic plaques generally form on the inside curvatures of arteries. The buildup of RBCs on the inside curvature is driven by the secondary flow and higher residence times. The higher viscosity in the central portion of the curved vessel tends to block their flow, causing them to migrate preferentially through the boundary layer. The reason for this is the nearly neutrally buoyant nature of the dense two-phase hemodynamic flow. The two-phase non-Newtonian viscosity model predicts greater shear thinning than the single-phase non-Newtonian model. Consequently, the secondary flow induced in the curvature is weaker. The waveforms for computed hemodynamic parameters, such as hematocrit, WSS, and viscosity, follow the prescribed inlet velocity waveforms. The lower oscillatory WSS produced on the inside curvature has implications for understanding thickening of the intimal layer.
منابع مشابه
Effect of six non-Newtonian viscosity models on hemodynamic parameters of pulsatile blood flow in stenosed artery
A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with non-Newtonian models using ADINA. Blood flow was considered laminar, and the arterial wall was considered rigid. Studied stenosis severities were 30, 50, and 70% of the cross-section...
متن کاملMultiphase non-Newtonian effects on pulsatile hemodynamics in a coronary artery
Hemodynamic stresses are involved in the development and progression of vascular diseases. This study investigates the influence of mechanical factors on the hemodynamics of the curved coronary artery in an attempt to identify critical factors of non-Newtonian models. Multiphase non-Newtonian fluid simulations of pulsatile flow were performed and compared with the standard Newtonian fluid model...
متن کاملNewtonian and Non-Newtonian Blood Flow Simulation after Arterial Stenosis- Steady State and Pulsatile Approaches
Arterial stenosis, for example Atherosclerosis, is one of the most serious forms of arterial disease in the formation of which hemodynamic factors play a significant role. In the present study, a 3-D rigid carotid artery with axisymmetric stenosis with 75% reduction in cross-sectional area is considered. Laminar blood flow is assumed to have both Newtonian and non-Newtonian behavior (generalize...
متن کاملAn advection-diffusion multi-layer porous model for stent drug delivery in coronary arteries
Arterial drug concentration distribution determines local toxicity. The safety issues dealt with Drug-Eluting Stents (DESs) reveal the needs for investigation about the effective factors contributing to fluctuations in arterial drug uptake. The current study focused on the importance of hypertension as an important and controversial risk factor among researchers on the efficacy of Heparin-Eluti...
متن کاملNumerical Study of Hemodynamic Wall Parameters on Pulsatile Flow through Arterial Stenosis
In this paper hemodynamic wall parameters which play an important role to diagnose arterial disease were studied and compared for three different rheology models (Newtonian, Power law and Quemada). Also because of the pulsatile behavior of blood flow the results were obtained for three Womersley numbers which represent the frequencies of the applied pulses. Results show that Quemada model alway...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomechanics
دوره 39 11 شماره
صفحات -
تاریخ انتشار 2006