Assessment of two commercial susceptibility test methods for determination of daptomycin MICs.

نویسندگان

  • James H Jorgensen
  • Sharon A Crawford
چکیده

Daptomycin is a lipopeptide antibiotic with activity against several important gram-positive bacterial pathogens, including drug-resistant staphylococci and enterococci. Because the mechanism of action of daptomycin is calcium-dependent depolarization of the cell membrane, susceptibility testing requires medium supplemented with a physiological level of calcium. This study assessed two Food and Drug Administration-cleared commercial test devices for determination of daptomycin MICs, Etest and JustOne. A collection of 220 selected isolates, including Staphylococcus aureus, coagulase-negative staphylococci, Enterococcus faecalis, E. faecium, E. avium, E. durans, E. casseliflavus, and E. gallinarum, were tested by both methods. Included in the collection were 22 S. aureus and 14 Enterococcus sp. isolates that were recovered from patients and were nonsusceptible on the basis of the daptomycin MICs. As the reference method for comparison, all isolates were tested by the Clinical and Laboratory Standards Institute broth microdilution method incorporating cation-adjusted Mueller-Hinton broth with 50 microg/ml calcium. Daptomycin MICs agreed, within 1 twofold dilution, for 97% of the isolates by Etest and for 100% by JustOne. However, daptomycin MICs determined by Etest were 1 dilution lower than the reference MICs for 65% of the Enterococcus sp. isolates tested. This resulted in 28.5% very major (VM) errors (4/14) with enterococci (all E. faecium) but none (0/22) with staphylococci. Use of JustOne yielded MICs that were 1 dilution lower than the reference MICs for 69% of the staphylococci and 25% of the enterococci. This resulted in 13.6% VM errors (3/22) with staphylococci and 14.3% VM errors (2/14) with enterococci. The manufacturer-recommended JustOne inoculum preparation resulted in mean colony counts of only 5 x 10(4) to 1 x 10(5) CFU/ml in the wells of the strip. Increasing the inoculum to 3 x 10(5) to 4 x 10(5) CFU/ml eliminated two of five VM errors upon retesting. No major interpretive errors occurred with either device. In summary, daptomycin MICs generated by the Etest or JustOne method generally agreed within 1 dilution of the reference daptomycin MICs. However, both devices produced slightly lower MICs that resulted in some VM errors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of vancomycin and daptomycin MICs by different testing methods for methicillin-resistant Staphylococcus aureus.

Vancomycin and daptomycin MICs from 161 isolates of methicillin-resistant Staphylococcus aureus (MRSA) were compared using commercial and in-house broth microdilution, Etest, and common automated methods. Vancomycin Etest MICs were higher than those of other methods, whereas the MICs for daptomycin testing were comparable. Vancomycin MICs vary depending on the testing methodology.

متن کامل

Daptomycin Susceptibility of Unusual Gram-Positive Bacteria: Comparison of the Etest and Broth Microdilution Method

Minimum inhibitory concentrations (MICs) of daptomycin, linezolid, and vancomycin against 212 isolates of Listeria monocytogenes, Pediococcus, Leuconostoc, Rhodococcus and Nocardia species were determined by the broth microdilution method and the Etest (daptomycin only). Except for Leuconostoc species, daptomycin Etest MICs showed >90% agreement with MICs by the broth microdilution method.

متن کامل

Reduced susceptibility to host-defense cationic peptides and daptomycin coemerge in methicillin-resistant Staphylococcus aureus from daptomycin-naive bacteremic patients.

BACKGROUND We hypothesized that, for methicillin-resistant Staphylococcus aureus (MRSA), in vitro daptomycin susceptibility could be influenced by exposures to endogenous host defense peptides (HDPs) prior to clinical exposure to daptomycin. METHODS Two endovascular HDPs were used: thrombin-induced platelet microbicidal protein (tPMP) and human neutrophil defensin-1 (hNP-1) from neutrophils. ...

متن کامل

Precision of vancomycin and daptomycin MICs for methicillin-resistant Staphylococcus aureus and effect of subculture and storage.

The reproducibility of vancomycin and daptomycin MICs, measured by broth microdilution (BMD) and Etest, was prospectively assessed for 10 methicillin-resistant Staphylococcus aureus (MRSA) isolates from the blood samples from patients on vancomycin therapy. The isolates were tested at the time of isolation from blood and following 5, 10, and 20 subcultures and at 1, 3, 6, and 12 months of stora...

متن کامل

Activities of antistaphylococcal antibiotics towards the extracellular and intraphagocytic forms of Staphylococcus aureus isolates from a patient with persistent bacteraemia and endocarditis.

Decreased susceptibility of Staphylococcus aureus to antistaphylococcal agents may be associated with inability to eradicate intracellular forms, which could explain therapeutic failures. This hypothesis was tested using clinical isolates obtained from a patient with persistent staphylococcal bacteraemia under therapy. Four isogenic isolates (three from tissue, one from blood) with increased MI...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 44 6  شماره 

صفحات  -

تاریخ انتشار 2006