Improved half RF slice selectivity in the presence of eddy currents with out-of-slice saturation.

نویسندگان

  • Sonal Josan
  • Elena Kaye
  • John M Pauly
  • Bruce L Daniel
  • Kim Butts Pauly
چکیده

Ultrashort echo time imaging with half RF pulse excitation is sensitive to eddy currents induced by the slice-select gradient that distorts the half pulse slice profile. This work demonstrates improvements in the half pulse profile by using spatial saturation on both sides of the imaged slice to suppress the out-of-slice magnetization. This effectively improves the selectivity of the half pulse excitation profile. A quadratic phase RF pulse with high bandwidth and selectivity was used to achieve a wide saturation band with sharp edges. Experimental results demonstrate substantially improved slice selectivity and R(2)* quantitation accuracy obtained with the out-of-slice saturation. This approach is effective in making short T(2) imaging and quantitation with half pulses less sensitive to eddy currents.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved Slice Excitation for Ultra-short TE Imaging with B0 and Linear Eddy Current Correction

INTRODUCTION MR imaging with ultra short echo times (UTEs) are of increasing interest to visualize tissues with short T2 or T2*, such as cartilage and ligaments, or monitoring the temperature during cryosurgery [1]. To achieve ultra-short TEs, a self-refocused half RF is usually used for excitation [2]. However, eddy currents induced by the selective gradient can result in undesirable slice pro...

متن کامل

Optimization of Radiation Dose in Cranial Computed Tomography among Adults: Assessment of Radiation Dose against Image Quality

Introduction: The rapid use of computed tomography (CT) scan is of great concern, due to increase in patients’ dose. Optimization of CT protocol is a vital issue in dose reduction. This study aimed to optimize radiation dose in cranial CT and assess modifications in image quality under radiation dose reduction. Material and Methods: A poly(me...

متن کامل

Optimization of Parameters in 16-slice CT-‌‌scan Protocols for Reduction of the Absorbed Dose

Introduction In computed tomography (CT) technology, an optimal radiation dose can be achieved via changing radiation parameters such as mA, pitch factor, rotation time and tube voltage (kVp) for diagnostic images. Materials and Methods In this study, the brain, abdomen, and thorax scaning was performed using Toshiba 16-slice scannerand standard AAPM and CTDI phantoms. AAPM phantom was used for...

متن کامل

Characterization of spontaneous network-driven synaptic activity in rat hippocampal slice cultures

A particular characteristic of the neonatal hippocampus is the presence of spontaneous network-driven oscillatory events, the so-called giant depolarizing potentials (GDPs). GDPs depend on the interplay between GABA and glutamate. Early in development, GABA, acting on GABAA receptors, depolarizes neuronal membranes via a Cl- efflux. Glutamate, via AMPA receptors, generates a positive feedback n...

متن کامل

Investigation of the effect of slice thickness and Kvp changes on the accuracy of linear measurements in CBCT: In vitro study

Background and Aim: The accuracy of linear measurements in CBCT images is one of the critical parameters in treatment planning. Slice thickness and exposure parameters seem to affect the accuracy of linear measurements. In this study, we investigated the impact of the above factors on the accuracy of linear measurements in CBCT. Materials and Methods: For the in vitro experiment, three dry huma...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 61 5  شماره 

صفحات  -

تاریخ انتشار 2009