Brtish Journal ofIndustrial Medicine 1982;39:259-264 Theoretical basis of alveolar sampling
نویسنده
چکیده
ABsTRAcr The conditions under which the partial pressure of a solvent in the alveolar gas is likely to provide a valid index of its partial pressure in the mixed venous blood, and thus of whole-body exposure, is explored on a theoretical basis. Under steady-state conditions, providing the solvent's blood/gas partition coefficient exceeds 10, its mixed venous and alveolar pressures will agree within 10% and become virtually identical during the prolonged expiration necessary to obtain an alveolar sample. With less soluble solvents, however, this is not necessarily so, and when the partition coefficient is less than three alveolar sampling is unlikely to provide a valid index of mixed venous levels. Abnormalities of pulmonary function, particularly ventilation/perfusion imbalance, are unltkely to alter these conclusions significantly.
منابع مشابه
Lower fiducial limit of urinary metabolite level as an index of excessive exposure to industrial chemicals.
Imamura, T., and Ikeda, M. (1973). British Journal ofIndustrial Medicine, 30, 289-292. Lower fiducial limit ofurinary metabolite level as an index ofexcessive exposure to industrial chemicals. Utilization ofthe lower fiducial limit (P = 0-10), rather than the mean, as an index ofexcessive exposure to industrial chemicals is discussed. Cases of exposure to trichloroethylene, phenol, and toluene ...
متن کاملAppendix A: Selected Case Studies of Ecosystem Contamination by Se
A1.0 Belews Lake, North Carolina ................................................................... 259 A1.1 Selenium Source ......................................................................... 259 A1.2 Fate and Transformation ............................................................ 259 A1.3 Effects .........................................................................................
متن کاملUltrasound Equipment Quality Assurance
Components of an Ultrasound Quality Assurance Program 257 Quality Assurance and Preventive Maintenance 257 Tissue-Mimicking Phantoms 257 Tissue Properties Represented in Phantoms 257 Typical Quality Assurance Phantom Design 257 Cautions About Phantom Desiccation 258 Basic Quality Control Tests 259 Visual Inspection 259 Transducer Choice 259 System Sensitivity 260 Photography and Gray-Scale Hard...
متن کاملThe Diagnostic Value of End-tidal Carbon Dioxide (EtCO2) and Alveolar Dead Space (AVDS) in Patients with Suspected Pulmonary Thrombo-embolism (PTE)
Introduction: Capnography, is an easy, fast and practical method which its application in the diagnosis of Pulmonary Thromboendarterectomy (PTE) has recently been studied. This study aimed to assess the diagnostic value of end-tidal CO2 (ETCO2) and the alveolar dead space (AVDS) in the diagnosis of patients suspected to PTE who have been referred to the emergency department. Materials and Metho...
متن کاملHydrophobic amino acid residues in the acceptor binding site are main determinants for reaction mechanism and specificity of cyclodextrin-glycosyltransferase.
Cyclodextrin-glycosyltransferases (CGTases) (EC ) preferably catalyze transglycosylation reactions with glucosyl residues as acceptor, whereas the homologous alpha-amylases catalyze hydrolysis reactions using water as acceptor. This difference in reaction specificity is most likely caused by the acceptor binding site. To investigate this in detail we altered the acceptor site residues Lys-232, ...
متن کامل