Techniques for precision irradiation of the lateral half of the rat cervical spinal cord using 150 MeV protons [corrected].

نویسندگان

  • P van Luijk
  • H P Bijl
  • R P Coppes
  • A J van der Kogel
  • A W Konings
  • J A Pikkemaat
  • J M Schippers
چکیده

Techniques for high precision irradiation experiments with protons, to investigate the volume dependence of the tolerance dose of the rat cervical spinal cord are described. In the present study, 50% of the lateral cross section of the spinal cord was irradiated. The diameter of the cross section of this part of the rat spinal cord is at maximum 3.5 mm. Therefore, a dedicated procedure was developed to comply with the needs for a very high positioning accuracy and high spatial resolution dosimetry. By using 150 MeV protons a steep dose gradient (20-80% = 1 mm) in the centre of the spinal cord was achieved. This yields a good dose contrast between the left and right halves of the cord. A home-made digital x-ray imager with a pixel resolution of 0.18 mm/pixel was used for position verification of the spinal cord. A positioning accuracy of 0.09 mm was obtained by using information of multiple pixels. The average position stability during the irradiation was found to be 0.08 mm (1 SD) without significant systematic deviations. Profiles of the dose distribution were measured with a 2D dosimetry system consisting of a scintillating screen and a CCD camera. Dose volume histograms of the whole spinal cord as well as separately of the white and grey matters were calculated using MRI imaging of the cross section of the rat cervical spinal cord. From the irradiation of 20 animals a dose-response curve has been established. MRI showed radiation-induced damage at the high dose side of the spinal cord. Analysis of the preliminary dose-response data shows a significant dose-volume effect. With the described procedure and equipment it is possible to perform high precision irradiations on selected parts of the spinal cord.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Chronological response of prostacyclin changes to moderately low doses of radiation in Rat cervical spinal cord

Background: Study of vascular and its secretory profile changes is an important issue in pathogenesis of radiation myelopathy. This paper reports the prostacyclin concentration changes after low-moderate doses of X-irradiation within a short period of time. Materials and Methods: Cervical cords of Wistar rats were irradiated to doses of 0.5, 1, 2, 4 and 6 Gy X-rays. After 24 hours, 2 and 13 ...

متن کامل

P9: Cervical Spinal Cord Extraction in Patients with Multiple Sclerosis Using Magnetic Resonance Imaging for Measuring Cross-Sectional Area

Multiple sclerosis (MS) refers to the lesions that accumulate in the brain and spinal cord. Magnetic resonance imaging (MRI) is the most sensitive and versatile modality used to show changes in the tissues over time. There has been significant interest in evaluating the relationship between the brain atrophy and disease progression rather than the spinal cord atrophy. The cervical spinal cord h...

متن کامل

Influence of adjacent low-dose fields on tolerance to high doses of protons in rat cervical spinal cord.

PURPOSE The dose-response relationship for a relatively short length (4 mm) of rat spinal cord has been shown to be significantly modified by adjacent low-dose fields. In an additional series of experiments, we have now established the dose-volume dependence of this effect. METHODS AND MATERIALS Wistar rats were irradiated on the cervical spinal cord with single doses of unmodulated protons (...

متن کامل

OMENTAL GRAFT APPLICABILITY IN EXPERIMENTALLY INDUCED SPINAL CORD COMPRESSION IN RATS

One of the most important factors responsible for axonal degeneration following spinal cord trauma is ischemia produced by cord compression. Previous studies have revealed that omental transposition upon the injured site of the spinal cord could be beneficial in the induction of partial improvement of neuroelectrical and motor function in laboratory animals. The purpose of this study is to...

متن کامل

An Assessment of Spinal Cord Dose Following Radiotherapy of Nasopharyngeal Cancer by TLD and Rando Phantom

Introduction: Nasopharyngeal carcinoma is one of the most common malignancies in the head and neck region and radiotherapy is its treatment of choice. In spite of the fact that it is widely used, due to the presence of many sensitive organs or tissues in this region, patients may suffer from a wide range of side effects. One such sensitive tissue is the spinal cord. If the absorbed dose to spin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 46 11  شماره 

صفحات  -

تاریخ انتشار 2001