An experimental characterization of elastographic spatial resolution: analysis of the trade-offs between spatial resolution and contrast-to-noise ratio.

نویسندگان

  • S Srinivasan
  • R Righetti
  • J Ophir
چکیده

An experimental study of the spatial resolution in elastography was conducted. Models that involved two cylindrical inclusions arranged as a wedge were used to characterize the axial and lateral resolution of the axial strain elastograms. A study of the dependence of the spatial resolution on several factors such as the algorithmic parameters, the applied strain and the modulus contrast was performed. The axial resolution was found to show a linear dependence with respect to the algorithmic parameters, namely the window length and the window shift used for strain estimation. The lateral resolution showed a weak dependence on the algorithmic parameters. A weak dependence of the spatial resolution on factors such as the modulus contrast and the applied strain was found. The trade-offs between the spatial resolution and the elastographic contrast-to-noise ratio (CNR(e)) were then analyzed. A nonlinear trade-off between the CNR(e) and the axial and lateral resolution was shown for conventional strain estimation techniques, with the CNR(e) improving at a more than linear rate with respect to a linear degradation in the resolution. This study provided an experimental framework for characterizing the spatial resolution in elastography and facilitating a comparison of the CNR(e) with spatial resolution.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of the effect of source distance and scattering medium on spatial resolution and contrast of Gamma camera images [Persian]

By identifying the effect of any parameter such as distance, attenuation and scattering on the Line Spread Function (LSF), one can compensate the quantitative and qualitative destructive effect of such parameters by deconvolution method. Using a 99mTC line source, this study was performed on a single head ADAC SPECT system operating in planar mode. Variation of FWTM and FWHM and LSFs as a...

متن کامل

A quality assurance program for an amorphous silicon electronic portal imaging device using in-house developed phantoms: a method development for dosimetry purposes

Background: Electronic portal imaging devices (EPIDs) play an important role in radiation therapy portal imaging, geometric and dosimetric verifications. A successful utilization of EPIDs for imaging and dosimetric purposes requires a reliable quality control process routine to be carried out regularly. In this study, two in-house phantoms were developed and analyzed for implementation in a qua...

متن کامل

Trade-offs between the axial resolution and the signal-to-noise ratio in elastography.

Elastography involves tracking the ultrasonic A-mode signals before and after mechanical compression of tissue to form a computed image of the local strains undergone by various tissue components. The quality of the strain estimates in elastography is typically quantified using factors such as the elastographic SNR (SNR(e)), contrast-to-noise ratio (CNR(e)), and the spatial resolution. These qu...

متن کامل

Speckle Reduction in Synthetic Aperture Radar Images in Wavelet Domain Exploiting Intra-scale and Inter-scale Dependencies

Synthetic Aperture Radar (SAR) images are inherently affected by a multiplicative noise-like phenomenon called speckle, which is indeed the nature of all coherent systems. Speckle decreases the performance of almost all the information extraction methods such as classification, segmentation, and change detection, therefore speckle must be suppressed. Despeckling can be applied by the multilooki...

متن کامل

Investigation of the Spatial Resolution and Field of View with Change of Magnification in VRX CT

Introduction: Variable resolution x-ray (VRX) CT is a new type of CT that can image objects at various spatial resolutions. In a VRX CT scanner, the spatial resolution increases at the cost of reduction in the field of view (FOV). An important factor that limits the spatial resolution of the VRX CT is the effect of focal spot size. Also, the optimum magnification is different at each incident a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Ultrasound in medicine & biology

دوره 30 10  شماره 

صفحات  -

تاریخ انتشار 2004