Tests of Micro - Pattern Gaseous Detectors for Active 1 Target Time Projection Chambers in nuclear physics

نویسندگان

  • S. Damoy
  • D. Perez Loureiro
  • V. Chambert
  • L. Suen
چکیده

9 Active target detection systems, where the gas used as the detection medium 10 is also a target for nuclear reactions, have been used for a wide variety of 11 nuclear physics applications since the eighties. Improvements in MPGD (Mi12 cro Pattern Gaseous Detectors) and in micro-electronics achieved in the last 13 decade permit the development of a new generation of active targets with 14 higher granularity pad planes that allow spatial and time information to be 15 determined with unprecedented accuracy. A novel active target and time 16 projection chamber (ACTAR TPC), that will be used to study reactions 17 and decays of exotic nuclei at facilities such as SPIRAL2, is presently un18 der development and will be based on MPGD technology. Several MPGD 19 (Micromegas and Thick GEM) coupled to a 2×2 mm pixellated pad plane 20 have been tested and their performances have been determined with differ21 ent gases over a wide range of pressures. Of particular interest for nuclear 22 physics experiments are the angular and energy resolutions. The angular 23 resolution has been determined to be better than 1◦ FWHM for short traces 24 of about 4 cm in length and the energy resolution deduced from the particle 25 range was found to be better than 5% for 5.5 MeV α particles. These per26 formances have been compared to Geant4 simulations. These experimental 27 results validate the use of these detectors for several applications in nuclear 28 physics. 29

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preliminary Characterization Tests of Detectors of on-Line Monitor Systems of the Italian National Center of Oncological Hadron-Therapy (CNAO)

Introduction Hadron-therapy is an effective technique used to treat tumors that are located between or nearby vital organs. The Italian National Center of Oncological Hadron-therapy (CNAO) has been realized as the first facility in Italy to treat very difficult tumors with protons and Carbon ions. The on-line monitor system for CNAO has been developed by the Department of Physics of the Univers...

متن کامل

Applications of triple GEM detectors beyond particle and nuclear

Micro-Pattern Gaseous Detectors (MPGD) have opened the way for the construction of detectors whose performance surpasses that of the previous generations in terms of spatial resolution, high-rate capability and increased radiation hardness. Led by the Micro-Mesh Gaseous Structure (Micromegas) and the Gas Electron Multiplier (GEM), some MPGDs are mature technologies used in a variety of experime...

متن کامل

EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH CERN-EP/2000-080 19 June 2000 GAS DETECTORS: ACHIEVEMENTS AND TRENDS

We describe recent developments of two areas of research on gaseous detectors: resistive plate chambers, aiming at best time resolution, and micropattern chambers, designed for high rate tracking in hostile environments. Emphasis is put on the progress in basic understanding of the operating features, and of the underlying physical processes. Some examples of applications of detectors outside p...

متن کامل

New Developments and Future Perspectives of Gaseous Detectors

Gaseous detectors are fundamental components of all present and planned high energy physics experiments. Over the past decade two representatives (GEM, Micromegas) of the Micro-Pattern Gas Detector (MPGD) concept have become increasingly important; the high radiation resistance and excellent spatial and time resolution make them an invaluable tool to confront future detector challenges at the n...

متن کامل

Fast System Matrix Calculation in CT Iterative Reconstruction

Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013