Visual and refractive outcomes following implantation of a new trifocal intraocular lens
نویسندگان
چکیده
BACKGROUND Independence from all optical aids, and freedom from unwanted symptoms, following cataract and lens surgery remains the ultimate goal of both patient and surgeon. The development of trifocal IOL technology provides an ever-increasing range of options. The purpose of our study is to understand the predictability, safety and efficacy of a new trifocal intraocular lens (IOL) following cataract or refractive lens exchange (RLE) surgery. METHODS This was a retrospective consecutive case series of patients undergoing cataract extraction or RLE followed by implantation of the Alcon IQ Panoptix IOL. Pre and postoperative refractive and visual parameters were recorded and evaluated. As the cohort followed a normal distribution, standard parametric tests were used. Paired t-test was used to compare the difference between target and postoperative refractive errors. The incidence of intraoperative and postoperative complications was also reported. RESULTS The IOL was implanted in 66 eyes of 33 patients. Mean postoperative spherical equivalent (SE) refraction was -0.08 ± 0.25 dioptres (D). This was not significantly different from the target refraction (p = 0.841). Sixty-five percent of patients were within ± 0.25 D of the target SE refraction with 100% within ± 0.50 D of intended correction. Mean postoperative uncorrected distance visual acuity (UDVA) was 0.01 ± 0.10 LogMAR. All patients achieved an unaided distance acuity of 20/40 or better postoperatively. Binocularly, 100% saw 0.20 LogMAR or better at near without correction and 88.9% achieved this level for uncorrected intermediate visual acuity. No intraoperative complications were noted. Five patients complained of moderate haloes in the early postoperative period. CONCLUSION The AcrySof IQ Panoptix IOL provides functional uncorrected visual acuity at distance, intermediate and near positions. Our results remain equivalent with existing trifocal IOL outcomes and provide surgeons with a further IOL alternative for the patient motivated to obtain true spectacle independence. Surgeons should consider individual reading and working requirements when counselling patients preoperatively to optimise postoperative patient satisfaction.
منابع مشابه
Clinical Outcomes after Binocular Implantation of a New Trifocal Diffractive Intraocular Lens
Purpose. To evaluate visual, refractive, and contrast sensitivity outcomes, as well as the incidence of pseudophakic photic phenomena and patient satisfaction after bilateral diffractive trifocal intraocular lens (IOL) implantation. Methods. This prospective nonrandomized study included consecutive patients undergoing cataract surgery with bilateral implantation of a diffractive trifocal IOL (A...
متن کاملVisual and refractive outcomes after implantation of a fully diffractive trifocal lens
BACKGROUND The purpose of this study was to record the visual outcomes of patients treated by six surgeons after implantation of a trifocal lens. METHODS The setting for this study comprised six ophthalmology units and eye clinics in Belgium and France, with a coordinating center in France, and data management and statistical analysis in France and Belgium. Ninety-four eyes from 47 patients w...
متن کاملVisual outcomes and subjective experience after bilateral implantation of a new diffractive trifocal intraocular lens.
PURPOSE To assess clinical outcomes and subjective experience after bilateral implantation of a diffractive trifocal intraocular lens (IOL). SETTING Midland Eye Institute, Solihull, United Kingdom. DESIGN Cohort study. METHODS Patients had bilateral implantation of Finevision trifocal IOLs. Uncorrected distance visual acuity, corrected distance visual acuity (CDVA), and manifest refractio...
متن کاملTitle Page TITLE: Visual outcomes and subjective experience following bilateral implantation of a new diffractive trifocal intraocular lens
متن کامل
Outcomes of a new diffractive trifocal intraocular lens.
PURPOSE To evaluate refractive and visual parameters related to distance, intermediate, and near vision after cataract surgery and the optical quality of a new diffractive trifocal intraocular lens (IOL). SETTING Vissum Instituto Oftalmologico de Alicante, Alicante, Spain. DESIGN Case series. METHODS Patients had bilateral refractive lens exchange and multifocal diffractive IOL (AT Lisa t...
متن کامل