Bone cement distribution in the vertebral body affects chances of recompression after percutaneous vertebroplasty treatment in elderly patients with osteoporotic vertebral compression fractures

نویسندگان

  • Liang Zhang
  • Qiang Wang
  • Lin Wang
  • Jian Shen
  • Qiwei Zhang
  • Changtai Sun
چکیده

OBJECTIVE Percutaneous vertebroplasty (PVP) is a surgical procedure that has been widely used to treat patients suffering from osteoporotic vertebral compression fractures (OVCFs). The procedure involves injection of bone cement into a fractured vertebra. In this study, we investigated whether the distribution of the cement in the vertebral body is related to the occurrence of recompression after surgery. PATIENTS AND METHODS A total of 172 patients diagnosed with OVCF, from January 2008 to June 2013, were retrospectively reviewed. Fifty of these patients experienced recompression after surgery during the follow-up period (recompression group), and 122 patients had no recompression observed during the follow-up period (control group). Statistical analysis was performed to compare clinical and operative parameters between these two groups. RESULTS Differences were found in bone cement distribution between the recompression group and control group (P=0.001). Patients with bone cement distributed around both upper and lower endplates had a significantly less incidence of recompression (4/50 patients), when compared to other patterns of cement distribution (eg, below upper endplate, above lower endplate, and in the middle of vertebral body). The logistic multiple regression analysis also indicated that patients with bone cement distributed around both the upper and lower endplates had a lower risk of recompression when compared to patients with bone cement distributed in the middle of vertebral body (odds ratio =0.223, P=0.003). CONCLUSION We herein suggest that the control of bone cement distribution during surgery provides beneficial effects on reducing the risks of recompression after PVP treatment in patients with OVCF.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Percutaneous Vertebroplasty in Iranian Patients with Osteoporotic Vertebral Fractures

Background: Osteoporotic compression vertebral fractures are common clinical problems. In those with refractory fractures, percutaneous cement augmentation has been suggested. The aim of this study was to evaluate the functional outcome of percutaneous vertebroplasty in Iranian patients with refractory osteoporotic fractures. Methods: We retrospectively studied 37 osteoporotic fractures in 28 p...

متن کامل

Percutaneous vertebroplasty for osteoporotic compression fractures using calcium phosphate cement.

PURPOSE To compare percutaneous transpedicular vertebroplasty using calcium phosphate cement (CPC) versus conservative treatment for osteoporotic vertebral fractures. METHODS Eight men and 28 women aged 61 to 99 (mean, 80) years with osteoporotic vertebral fractures underwent percutaneous transpedicular vertebroplasty using CPC. During the same period, 6 men and 32 women aged 53 to 93 (mean, ...

متن کامل

Percutaneous vertebroplasty for symptomatic osteoporotic vertebral compression fracture adjacent to lumbar instrumented circumferential fusion.

The purpose of this study was to evaluate the efficacy and safety of percutaneous vertebroplasty for patients with symptomatic osteoporotic vertebral compression fractures adjacent to lumbar instrumented circumferential fusion. Between January 2005 and June 2010, eighteen patients in the authors' institution with lumbar instrumented circumferential fusion had adjacent symptomatic osteoporotic v...

متن کامل

Treating osteoporotic vertebral compression fractures with intraosseous vacuum phenomena using high-viscosity bone cement via bilateral percutaneous vertebroplasty

Osteoporotic vertebral compression fractures with intraosseous vacuum phenomena could cause persistent back pains in patients, even after receiving conservative treatment. The aim of this study was to evaluate the efficacy of using high-viscosity bone cement via bilateral percutaneous vertebroplasty in treating patients who have osteoporotic vertebral compression fractures with intraosseous vac...

متن کامل

An ex vivo biomechanical evaluation of an inflatable bone tamp used in the treatment of compression fracture.

STUDY DESIGN Ex vivo biomechanical study using osteoporotic cadaveric vertebral bodies. OBJECTIVES To determine if the inflatable bone tamp (tamp) restores height to compressed vertebral bodies and to compare the biomechanical properties of isolated, fractured osteoporotic vertebral bodies treated by kyphoplasty (tamp) or vertebroplasty. SUMMARY OF BACKGROUND DATA Previous biomechanical stu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017