Withdrawing intra-aortic balloon pump support paradoxically improves microvascular flow
نویسندگان
چکیده
INTRODUCTION The Intra-Aortic Balloon Pump (IABP) is frequently used to mechanically support the heart. There is evidence that IABP improves microvascular flow during cardiogenic shock but its influence on the human microcirculation in patients deemed ready for discontinuing IABP support has not yet been studied. Therefore we used sidestream dark field imaging (SDF) to test our hypothesis that human microcirculation remains unaltered with or without IABP support in patients clinically ready for discontinuation of mechanical support. METHODS We studied 15 ICU patients on IABP therapy. Measurements were performed after the clinical decision was made to remove the balloon catheter. We recorded global hemodynamic parameters and performed venous oximetry during maximal IABP support (1:1) and 10 minutes after temporarily stopping the IABP therapy. At both time points, we also recorded video clips of the sublingual microcirculation. From these we determined indices of microvascular perfusion including perfused vessel density (PVD) and microvascular flow index (MFI). RESULTS Ceasing IABP support lowered mean arterial pressure (74 ± 8 to 71 ± 10 mmHg; P = 0.048) and increased diastolic pressure (43 ± 10 to 53 ± 9 mmHg; P = 0.0002). However, at the level of the microcirculation we found an increase of PVD of small vessels <20 μm (5.47 ± 1.76 to 6.63 ± 1.90; P = 0.0039). PVD for vessels >20 μm and MFI for both small and large vessels were unaltered. During the procedure global oxygenation parameters (ScvO2/SvO2) remained unchanged. CONCLUSIONS In patients deemed ready for discontinuing IABP support according to current practice, SDF imaging showed an increase of microcirculatory flow of small vessels after ceasing IABP therapy. This observation may indicate that IABP impairs microvascular perfusion in recovered patients, although this warrants confirmation.
منابع مشابه
The Evaluation of Survival in Patients Who Need Intra Aortic Balloon Pump (IABP) after Cardiac Surgery
Introduction: Insome cases, assist devices are required to ensure an adequate cardiac output after cardiac surgery. Intra-aortic balloon pump (IABP) is the most commonly used cardiac assist device, which provides first-line support for patients with heart failure. The aim of this study was to determine factors affecting the mortality rate of patients receiving IABP. Materials & Methods: In thi...
متن کاملMicrocirculation in cardiogenic shock: from scientific bystander to therapy target
Despite diagnostic and therapeutic improvements, mortality rates in patients with cardiogenic shock remain relatively high. Several studies showed that cardiogenic shock is associated with alterations in the microvascular circulation. These alterations may be reversed by extracorporeal support devices. A study by Munsterman and colleagues adds to the body of evidence showing that in patients de...
متن کاملComputational analysis of aortic hemodynamics during total and partial extracorporeal membrane oxygenation and intra-aortic balloon pump support.
PURPOSE The extracorporeal membrane oxygenation (ECMO) is a temporary, but prolonged circulatory support for cardiopulmonary failure. Clinical evidence suggests that pulsed flow is healthier than non pulsatile perfusion. The aim of this study was to computationally evaluate the effects of total and partial ECMO assistance and pulsed flow on hemodynamics in a patient-specific aorta model. METH...
متن کاملCoronary and microvascular physiology during intra-aortic balloon counterpulsation.
OBJECTIVES This study sought to identify the effect of coronary autoregulation on myocardial perfusion during intra-aortic balloon pump (IABP) therapy. BACKGROUND IABP is the most commonly used circulatory support device, although its efficacy in certain scenarios has been questioned. The impact of alterations in microvascular function on IABP efficacy has not previously been evaluated in hum...
متن کاملReversed intracranial blood flow in patients with an intra-aortic balloon pump.
As a preliminary investigation into the cerebral effects of mechanical cardiac assist devices, using transcranial Doppler ultrasonography I examined the basal cerebral arteries in three patients placed on an intra-aortic balloon pump. Unassisted systoles had normal blood velocities and waveforms. When the pump was in use, diastolic blood velocity during balloon inflation increased. As the ballo...