Motion limitations of non-contact photoplethysmography due to the optical and topological properties of skin.

نویسندگان

  • M J Butler
  • J A Crowe
  • B R Hayes-Gill
  • P I Rodmell
چکیده

Non-contact photoplethysmography (PPG) provides multiple benefits over in-contact methods, but is not as tolerant to motion due to the lack of mechanical coupling between the subject and sensor. One limitation of non-contact photoplethysmography is discussed here, specifically looking at the topology and optical variations of the skin and how this impacts upon the ability to extract a photoplethysmogram when a subject moves horizontally across the field of view of the detector (a panning motion). When this occurs it is shown that whilst the general relationships between the speed of traversal, detection area and resultant signal quality can be found, the quality of signal in each individual case is determined by the properties of the area of skin chosen.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of Photoplethysmography Method in Extraction of Hemoglobin Concentration

Background: The importance of continuous monitoring along with rapid and accurate notification of changes in blood components such as hemoglobin concentration, especially in acute situations, encourages researchers to use non-invasive methods for measuring.Objective: This study was aimed to investigate the correlation between hemoglobin concentration and photoplethysmogram (PPG) and the p...

متن کامل

Increasing the Accuracy of Blood Hematocrit Measurement by Triplicate Wavelength Photoplethysmography Method

Background and objectives: The importance of continuous monitoring and rapid and accurate informing of changes in blood components (e.g., percentage of hematocrit [HCT]), especially in acute conditions, has motivated researchers to use non-invasive measurement methods. Therefore, this study aimed to evaluate the association between blood HCT and photoplethysmographic signal and the possibility ...

متن کامل

Drill string Vibration Modeling Including Coupling Effects

Abstract: The governing equations of motion for a drill string considering coupling between axial, lateral and torsional vibrations are obtained using a Lagrangian approach. The result leads to a set of non-linear equations with time varying coefficients. A fully coupled model for axial, lateral, and torsional vibrations of drill strings is presented. The bit/formation interactions are assumed ...

متن کامل

Using photoplethysmography in heart rate monitoring of patients with epilepsy.

Heart rate is a useful neurophysiological sign when monitoring seizures in patients with epilepsy. In an ambulatory setting, heart rate is measured with ECG involving electrodes on the skin. This method is uncomfortable which is burdensome for patients and is sensitive to motion artifacts, which decrease the usability of measurements. In this study, green light photoplethysmography, an optical ...

متن کامل

Towards Measurement of Polarization Properties of Skin using the Ellipsometry Technique

Introduction: The human skin is an active medium from the optical point of view. Therefore, the diagnostic and therapeutic techniques employing light are increasing. Current optical techniques are based on the measurement of the intensity of reflected absorbed or backscattered light from or within skin. Studies have shown that biological tissues, and in particular skin, demonstrate polarization...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physiological measurement

دوره 37 5  شماره 

صفحات  -

تاریخ انتشار 2016