Retrospective clinical evaluation of tapered screw-vent implants: results after up to eight years of clinical function.
نویسندگان
چکیده
Uncertainty about the causes of peri-implant bone loss and difficulties in measuring it often have resulted in omission of bone loss data from published long-term implant studies. This nonrandomized, uncontrolled, retrospective study evaluated the clinical outcomes of treatment with tapered, multithreaded implants with a special emphasis on peri-implant crestal bone status. Chart reviews were conducted of 60 patients who had been treated with 267 implants for the placement of 1 or more missing and/or unsalvageable teeth, and who met general inclusion criteria for dental implant therapy. In all cases, marginal bone changes were calculated from the cementoenamel junction (CEJ) or the implant neck to the crestal bone level with standardized radiographs taken at implant placement (baseline) and during annual follow-up. After a mean followup of 7.5 years, implant survival was 98.5% (263/267) for all implants placed, and implant success was 96.2% (253/263) for all surviving implants. No discernible bone loss was evident in 88% of surviving implants. Crestal bone loss was observed in 25% (15/60) of total study subjects and in 12% (32/263) of all surviving implants: 29 implants exhibited 1 mm of bone loss and 3 implants lost 2 mm of bone. Low-density maxillary jawbone and more extensive bone remodeling, which were required around implants immediately placed into extraction sockets, were the probable causes of observed bone loss in this study. Implants exhibited excellent long-term outcomes with little or no bone loss.
منابع مشابه
The clinical effectiveness of screw type Implant “Nisastan system” in the posterior region of the mandible: A 2 year prospective study
The clinical effectiveness of screw type Implant “Nisastan system” in the posterior region of the mandible: A 2 year prospective study Dr. M. Rismanchian * - Dr. R. Birang ** * Assistant Professor of Fixed Prosthodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ** Assistant Professor of Periodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences....
متن کاملRetrospective clinical evaluation of tapered implants: 10-year follow-up of delayed and immediate placement of maxillary implants.
OBJECTIVES To retrospectively evaluate the clinical outcome of tapered, multithreaded implants (Tapered Screw-Vent MTX; Zimmer Dental, Inc, Carlsbad, CA) with an emphasis on periimplant crestal bone status around those placed delayed and immediately in the posterior and anterior maxilla. METHODS Chart reviews were performed on 46 patients who had been treated with 173 implants replacing one o...
متن کاملClinical evaluation of soft tissue surrounding prosthesis supported by implants
Clinical evaluation of soft tissue surrounding prosthesis supported by implants Dr. A. Fazel* - Dr. M. Rismanchian** *- Associate Professor of Prosthodontics Dept. - Faculty of Dentistry - Tehran University of Medical Sciences. **- Assistant Professor of Prosthodontics Dept. – Faculty of Dentistry - Isfahan University of Medical Sciences. Background and Aim: Nowadays, reconstruction and replace...
متن کاملA 6-year Evaluation of 223 Tapered Dental Implants and associated prosthesis in 92 patients at a University Hospital.
The aim of the retrospective study was to assess the clinical and radiographic outcome of the dental implant surgery and prosthetics. It was conducted at the Aga Khan University Hospital, Karachi, and comprised of medical charts and radiographic records of patients visiting between 2010 and 2015. Variables such as implant dimensions, final prosthesis, method of retention, loading protocol and p...
متن کاملCement- and screw-retained implant-supported prostheses: up to 10 years of follow-up of a new design.
PURPOSE This retrospective study investigated treatment outcomes over 10 years of a new prosthesis design in implant prosthodontics that uses a combined cement- and screw-retained principle. MATERIALS AND METHODS The clinical data of 78 implant-supported prostheses were examined. Each prosthesis incorporated at least 1 screw-retained element and 1 or more cement-retained telescopic units. One...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of oral implantology
دوره 34 3 شماره
صفحات -