Uncemented femoral revision arthroplasty using a modular tapered, fluted titanium stem

نویسندگان

  • Dieter C Wirtz
  • Sascha Gravius
  • Rudolf Ascherl
  • Raimund Forst
  • Ulrich Noeth
  • Uwe M Maus
  • Günther Zeiler
  • Deml Moritz C
چکیده

BACKGROUND AND PURPOSE Due to the relative lack of reports on the medium- to long-term clinical and radiographic results of modular femoral cementless revision, we conducted this study to evaluate the medium- to long-term results of uncemented femoral stem revisions using the modular MRP-TITAN stem with distal diaphyseal fixation in a consecutive patient series. PATIENTS AND METHODS We retrospectively analyzed 163 femoral stem revisions performed between 1993 and 2001 with a mean follow-up of 10 (5-16) years. Clinical assessment included the Harris hip score (HHS) with reference to comorbidities and femoral defect sizes classified by Charnley and Paprosky. Intraoperative and postoperative complications were analyzed and the failure rate of the MRP stem for any reason was examined. RESULTS Mean HHS improved up to the last follow-up (37 (SD 24) vs. 79 (SD 19); p<0.001). 99 cases (61%) had extensive bone defects (Paprosky IIB-III). Radiographic evaluation showed stable stem anchorage in 151 cases (93%) at the last follow-up. 10 implants (6%) failed for various reasons. Neither a breakage of a stem nor loosening of the morse taper junction was recorded. Kaplan-Meier survival analysis revealed a 10-year survival probability of 97% (95% CI: 95-100). INTERPRETATION This is one of the largest medium- to long-term analyses of cementless modular revision stems with distal diaphyseal anchorage. The modular MRP-TITAN was reliable, with a Kaplan-Meier survival probability of 97% at 10 years.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tapered modular fluted titanium stems for femoral fixation in revision total knee arthroplasty

Consensus regarding femoral stem fixation options in revision total knee arthroplasty remains controversial. Tapered, modular, fluted titanium (TMFT) stems have an excellent track record in total hip arthroplasty for their ability to provide axial and rotational stability in situations of compromised host bone. We present 3 successfully treated cases in which the Food & Drug Administration gran...

متن کامل

Osteointegration of an uncemented modular revision stem implanted during revision hip surgery.

BACKGROUND Though mid-term survival rates of over 95% in several series have been published, there is still a paucity of related literature regarding the role of vertical stem instability in the osteointegration of fluted tapered stems. This paper presents a comprehensive and prospective assessment on short-term experiences with uncemented modular femoral stem in the treatment of defective femu...

متن کامل

Elevated Serum Titanium Level as a Marker for Failure in a Titanium Modular Fluted Tapered Stem.

Serum ion concentrations of cobalt and chromium are commonly used to monitor for the development of local metal reactions in metal-on-metal total hip arthroplasties, as well as dual-modular constructs. Although rarely used in clinical practice, elevated serum titanium levels have the ability to indicate a failure with contemporary revision constructs, such as with titanium modular fluted tapere...

متن کامل

Modular tapered titanium stems in revision arthroplasty of the hip: The Risk and Causes of Stem Fracture.

Tapered fluted titanium stems are increasingly used for femoral revision arthroplasty. They are available in modular and non-modular forms. Modularity has advantages when the bone loss is severe, the proximal femur is mis shapen or the surgeon is unfamiliar with the implant, but it introduces the risk of fracture of the stem at the junction between it and the proximal body segment. For that rea...

متن کامل

Medium-term outcome of titanium uncemented stems in revision total hip arthroplasty.

PURPOSE To assess the medium-term outcome of titanium uncemented modular tapered stems in revision total hip arthroplasty (THA). METHODS A questionnaire was mailed to 421 patients who underwent revision THA using a titanium uncemented modular tapered stem. 66 of whom underwent re-revision THA. The questionnaire was composed to reveal the Charnley classification, the modified 12-item Oxford hi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 85  شماره 

صفحات  -

تاریخ انتشار 2014