Optimal Sensor Placement for FDI using Binary Integer Linear Programming
نویسندگان
چکیده
Abstract: This work is devoted to find an optimal set of sensors for model-based FDI. The novelty is that binary integer linear programming is used in the optimization problem, leading to a formulation of the detectability and isolability specifications as linear inequality constraints. Furthermore, a very detailed system model is not needed since the methodology handles structural models. The approach has been successfully applied to a two-tank system, as an illustrative example.
منابع مشابه
Model-based Optimal Sensor Placement Approaches to Fuel Cell Stack System Fault Diagnosis
The problem of optimal sensor placement for FDI consists in determining the set of sensors that minimizes a pre-defined cost function satisfying at the same time a pre-established set of FDI specifications for a given set of faults. This paper recalls three model-based optimal sensor location approaches: an Incremental search, a Heuristic search and a Binary Integer Linear Programming (BILP) fo...
متن کاملOptimal PMU Placement Considering with HVDC Links and Their Voltage Stability Requirements
In wide area measurement systems, PMUs are the main component measuring real time synchronized data from different buses. Installation of PMUs at all buses is a primary way to provide full observability of the power network. However, it is not practical in real networks due to the relatively expensive cost of PMUs and other technical limitations. Optimal PMU Placement (OPP) is an optimization p...
متن کاملAn L1-norm method for generating all of efficient solutions of multi-objective integer linear programming problem
This paper extends the proposed method by Jahanshahloo et al. (2004) (a method for generating all the efficient solutions of a 0–1 multi-objective linear programming problem, Asia-Pacific Journal of Operational Research). This paper considers the recession direction for a multi-objective integer linear programming (MOILP) problem and presents necessary and sufficient conditions to have unbounde...
متن کاملA Multiple-Objective Analysis of Sensor Placement Optimization in Water Networks
Terrorism concerns have recently led to increased interest in the potential use of sensors to detect malicious attacks on municipal water systems. A key deployment issue is identifying where the sensors should be placed in order to maximize the level of protection. Researchers have proposed several algorithms for constructing such sensor placements, each optimizing with respect to a different d...
متن کاملA Novel Approach for the Optimal PMU Placement using Binary Integer Programming Technique
Phasor measurement units (PMUs) are considered as a promising tool for future monitoring, protection and control of power systems. In this paper, a novel approach is proposed in order to determine the optimal number and locations of PMUs to make the power system observable. The PMU placement problem is formulated as a binary integer linear programming, in which the binary decision variables (0,...
متن کامل