Field evaluation of digital optical method to quantify the visual opacity of plumes.

نویسندگان

  • Ke Du
  • Mark J Rood
  • Byung J Kim
  • Michael R Kemme
  • Bill J Franek
  • Kevin Mattison
  • Joan Cook
چکیده

Visual Determination of the Opacity of Emissions from Stationary Sources (Method 9) is a reference method established by U.S. Environmental Protection Agency (EPA) to quantify plume opacity. However, Method 9 relies on observations from humans, which introduces subjectivity. In addition, it is expensive to teach and certify personnel to evaluate plume opacity on a semiannual basis. In this study, field tests were completed during a "smoke school" and a 4-month monitoring program of plumes emitted from stationary sources with a Method 9 qualified observer to evaluate the use of digital photography and two computer algorithms as an alternative to Method 9. This Digital Optical Method (DOM) improves objectivity, costs less to implement than Method 9, and provides archival photographic records of the plumes. Results from "smoke school" tests indicate that DOM passed six of eight tests when the sun was located in the 140 degrees sector behind one of the three cameras, with the individual opacity errors of 15% or less and average opacity errors of 7.5% or less. DOM also passed seven of the eight tests when the sun was located in the 216 degrees sector behind another camera. However, DOM passed only one of the eight tests when the sun was located in the 116 degrees sector in front of the third camera. Certification to read plume opacity by a "smoke reader" for 6 months requires that the "smoke reader" pass one of the smoke school tests during smoke school. The average opacity errors and percentage of observations with individual opacity errors above 15% for the results obtained with DOM were lower than those obtained by the smoke school trainees with the sun was located behind the camera, whereas they were higher than the smoke school trainee results with the sun located in front of the camera. In addition, the difference between plume opacity values obtained by DOM and a Method 9 qualified observer, as measured in the field for two industrial sources, were 2.2%. These encouraging results demonstrate that DOM is able to meet Method 9 requirements under a wide variety of field conditions and, therefore, has potential to be used as an alternative to Method 9.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of digital optical method to determine plume opacity during nighttime.

United States Environmental Protection Agency (USEPA) set opacity standards for visual emissions from industrial sources to protect ambient air quality. USEPA developed Method 9, which is a reference method to describe how plume opacity can be quantified by human observers during daytime conditions. However, it would be beneficial to determine plume opacity with digital still cameras (DSCs) to ...

متن کامل

Quantification of plume opacity by digital photography.

The United States Environmental Protection Agency (USEPA) developed Method 9 to describe how plume opacity can be quantified by humans. However, use of observations by humans introduces subjectivity, and is expensive due to semiannual certification requirements of the observers. The Digital Opacity Method (DOM) was developed to quantify plume opacity at lower cost, with improved objectivity, an...

متن کامل

Field Testing of the Digital Opacity Method to Quantify Plume Opacity

U.S. Environmental Protection Agency (USEPA) established Method 9 as a standard method to quantify plume opacity. However, there are issues about the subjectivity of such method . The appearance of the plume to human observations can be affected by many factors, such as the angle of the sun, the time of the day and the geographic location of the source . A new digital photographic method, Digit...

متن کامل

Performance Evaluation of Detector Algorithms of Dust Storms in Arid Lands (Case Study: Yazd Province)

Introduction: In recent years, frequency and intensity of dust storms have been increased because of human destructive activities and caused significant loss in different aspects of hygienic and health, environmental and socio-economic sections. Therefore, detection and trace of dust storms in shortest time is the first effective step in preparation and implementation of strategic and operation...

متن کامل

Measuring visual opacity using digital imaging technology.

The U.S. Environmental Protection Agency (EPA) Reference Method 9 (Method 9) is the preferred enforcement approach for verifying facility compliance with federal visible opacity standards. Supporters of Method 9 have cited its flexibility and low cost as important technological and economic advantages of the methodology. The Digital Opacity Compliance System (DOCS), an innovative technology tha...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the Air & Waste Management Association

دوره 57 7  شماره 

صفحات  -

تاریخ انتشار 2007