ARM: a modular hinged joint for the AO tubular external fixator.

نویسندگان

  • Alfonso Queipo de Llano Temboury
  • Rafael López Arévalo
  • Felipe Luna González y Enrique Queipo de Lllano Jiménez
چکیده

Certain complex traumatic elbow lesions challenge the orthopaedic and trauma surgeon. If they are not treated correctly, they cause a high rate of disability, arising from elbow instablility and stiffness, either by fibrosis or joint incongruity. Injuries such as complex fractures of the proximal third of the ulna, coronoid fractures associated with radial head fractures (the "terrible triad"), are even worse if they are accompanied by soft tissue lesions. Hinged external fixators, complemented by other surgical procedures, are, for many, a recommended alternative when dealing with irreparable lesions. The AO tubular external fixator, by virtue of its versatility, is a very important tool in orthopaedics and trauma, but there is not the possibility of using it as a hinged fixator. The authors describe a prototype of a hinged joint that can be applied easily to the AO tubular external fixator, converting it into a hinged one. This hinged joint, in conjunction with the AO tubular external fixator, has been applied in 5 patients; 2 "terrible triads", one posterior elbow fracture-dislocation with radial head fracture, one Monteggia fracture-dislocation and an anterior elbow dislocation that developed a forearm compartment syndrome. The patients' age range was between 20 and 72 years (median 45,6); 4 were male and 1 female. In 3 patients, either a type III coronoid fracture or a radial head fracture, could not be repaired. One radial head was totally removed and another one partially removed. The remaining indications were because of severe soft tissue lesions. Results were evaluated using the Mayo Elbow Score Scale and the Broberg and Morrey radiographic evaluation scale. The median follow up was 18 months(range 6 to 48 months). All 5 patients got a maximum score of 100 points in the Mayo's Elbow Score Scale, indicating excellent results. No patient suffered elbow pain, or any type of elbow instability. The median range of motion in flexion was of 127.5 degrees (max. 140 degrees and min. 120 degrees ) and the median extension loss was 20 degrees (max. 25 degrees and min. 15 degrees ). One patient had pronation limited to 70 degrees and one had supination limited to 70 degrees . Every patient was able to resume a normal daily life activity and returned to normal work. In 3 patients the radiographic evaluation was Grade 0 and in the other 2, Grade I. Two complications occurred, one was a distal ulnar Schanz screw loosening with osteolysis and the other was a superficial infection of one Schanz screw. It can be concluded that good results can be obtained in injuries with severe elbow instability and soft tissue lesions, using this hinged external fixator. With this new clamp, the AO tubular external fixator is transformed into a hinged one and a new use is added to this already very versatile system. This clamp is very easy to apply.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The use of hinged external fixation to provide additional stabilization for fractures of the distal humerus.

OBJECTIVE To assess improvements in fixation stability when a hinged unilateral external fixator is used to supplement compromised internal fixation for distal humerus fractures. METHODS Removing a 1-cm section of the distal humerus in cadaveric whole-arm specimens created a comminuted distal humerus fracture model (AO type 13-A3). Fixation was then performed using different constructs repres...

متن کامل

Hinged external fixator and open surgery for severe elbow stiffness with distal humeral nonunion.

Joint stiffness is a common complication of elbow trauma. Treating elbow stiffness is challenging, especially in patients with severe elbow stiffness with distal humeral nonunion. To improve treatment outcomes, the authors applied a hinged external fixator after performing open reduction and internal fixation and evaluated the clinical outcome. Between 2005 and 2011, eleven patients with elbow ...

متن کامل

Ilizarov Versus AO External Fixator for the Treatment of Tibia Open Fractures

BACKGROUND In developing countries, Ilizarov or AO external fixator is usually used for treatment of tibial open fractures. The purpose of this study was to compare the efficacy of these two methods for treatment of tibial open fractures. METHODS From April 2002 to April 2010, 120 patients with open tibial fractures admitted to the Department of Orthopedics of Babol University of Medical Scie...

متن کامل

Hinged external fixation of the elbow: optimal axis alignment to minimize motion resistance.

OBJECTIVE To establish an optimal single hinge axis position for application of hinged external fixation to the elbow joint. DESIGN Cadaveric biomechanical investigation. SETTING A customized motion transducer applied passive elbow motion to six cadaveric upper extremities. The instant rotation axis of the humero-ulnar articulation was determined from three-dimensional kinematic data acquir...

متن کامل

A hinged external fixator for complex elbow dislocations: A multicenter prospective cohort study

BACKGROUND Elbow dislocations can be classified as simple or complex. Simple dislocations are characterized by the absence of fractures, while complex dislocations are associated with fractures of the radial head, olecranon, or coronoid process. The majority of patients with these complex dislocations are treated with open reduction and internal fixation (ORIF), or arthroplasty in case of a non...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Techniques in hand & upper extremity surgery

دوره 10 1  شماره 

صفحات  -

تاریخ انتشار 2006