Determinants of LV diastolic function during atrial fibrillation: beat-to-beat analysis in acute dog experiments.

نویسندگان

  • Tomotsugu Tabata
  • Richard A Grimm
  • Junko Asada
  • Zoran B Popovic
  • Hirotsugu Yamada
  • Neil L Greenberg
  • Don W Wallick
  • Youhua Zhang
  • Shaowei Zhuang
  • Kent A Mowrey
  • James D Thomas
  • Todor N Mazgalev
چکیده

Left ventricular (LV) diastolic function during atrial fibrillation (AF) remains poorly understood due to the complex interaction of factors and beat-to-beat variability. The purpose of the present study was to elucidate the physiological determinants of beat-to-beat changes in LV diastolic function during AF. The RR intervals preceding a given cardiac beat were measured from the right ventricular electrogram in 12 healthy open-chest mongrel dogs during AF. Doppler echocardiography and LV pressure and volume beat-to-beat analyses were performed. The LV filling time (FT) and early diastolic mitral inflow velocity-time integral (E(vti)) were measured using the pulsed Doppler method. The LV end-diastolic volume (EDV), peak systolic LV pressure (LVP), minimum value of the first derivative of LV pressure curve (dP/dt(min)), and the time constant of LV pressure decay (tau) were evaluated with the use of a conductance catheter for 100 consecutive cardiac cycles. Beat-to-beat analysis revealed a cascade of important causal relations. LV-FT showed a significant positive linear relationship with E(vti) (r = 0.87). Importantly, there was a significant positive linear relationship between the RR interval and LV-EDV in the same cardiac beat (r = 0.53). Consequently, there was a positive linear relationship between LV-EDV and subsequent peak systolic LVP (r = 0.82). Furthermore, there were significant positive linear and negative curvilinear relationships between peak systolic LVP and dP/dt(min) (r = 0.95) and tau (r = -0.85), respectively, in the same cardiac beat. In addition, there was a significant negative curvilinear relationship between dP/dt(min) and tau (r = -0.86). We have concluded that the determinants of LV diastolic function in individual beats during AF depend strongly on the peak systolic LVP. This suggests that the major benefit of slower ventricular rate appears related to lengthening of LV filling interval, promoting subsequent higher peak systolic LVP and greater LV relaxation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Left ventricular beat to beat performance in atrial fibrillation: dependence on contractility, preload, and afterload.

OBJECTIVE To assess independent determinants of beat to beat variation in left ventricular performance during atrial fibrillation. DESIGN Prospective study. SETTING University hospital. PATIENTS Seven patients with chronic non-valvar atrial fibrillation. INTERVENTIONS Invasive and non-invasive haemodynamic variables were assessed using a non-imaging computerised nuclear probe, a balloon...

متن کامل

Left Ventricular Systolic Function is Sensitive to Cycle-Length Irregularity in Patients with Atrial Fibrillation and Systolic Dysfunction

Background: Left ventricular (LV) systolic function during atrial fibrillation (AF) is positively correlated with an index of ventricular cycle-length irregularity, the ratio of preceding R-R interval to pre-preceding R-R interval (RRp/RRpp). This study was designed to elucidate the relationship between the RRp/RRpp ratio and LV function, and to identify factors which influence the relationship...

متن کامل

Normal distribution of ventricular pressure-volume area of arrhythmic beats under atrial fibrillation in canine heart.

We previously found the frequency distribution of the left ventricular (LV) effective afterload elastance (E(a)) of arrhythmic beats to be nonnormal or non-Gaussian in contrast to the normal distribution of the LV end-systolic elastance (E(max)) in canine in situ LVs during electrically induced atrial fibrillation (AF). These two mechanical variables determine the total mechanical energy [systo...

متن کامل

Effects Of Fast Pathway Ablation On The Concealment Zone And Electrophysiological Behavior Of AV-Node During Atrial Fibrillation.

Objectives: Dual pathways have a determinant role in the occurrence of atrio nodal tachyarrhythmia (AVNRT). The aim of present study is to determine the role of slow pathway (SP) in the concealment zone and protective role of AV node during atrial fibrillation (AF). Material &Methods: In 7 isolated nodal rabbit preparation zone of concealment and concealed conduction is quantified by Specif...

متن کامل

Left ventricular beat-to-beat performance in atrial fibrillation: contribution of Frank-Starling mechanism after short rather than long RR intervals.

OBJECTIVES This study sought to evaluate control mechanism of the varying left ventricular performance in atrial fibrillation. BACKGROUND Atrial fibrillation is characterized by a randomly irregular ventricular response, resulting in continuous variation in left ventricular beat-to-beat mechanical behavior and hemodynamic variables. METHODS Fourteen patients with chronic nonvalvular atrial ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 286 1  شماره 

صفحات  -

تاریخ انتشار 2004