Evaluation of the spectrophotometric assay of guanase with 2,2'-azino-di(3-ethylbenzthiazoline-6-sulphonate) (ABTS) as chromogen.

نویسندگان

  • N Majkić-Singh
  • D Popović
  • S Spasić
چکیده

A simple spectrophotometric assay for serum guanase based on the oxidation of 2,2'-azino-di(3-ethylbenzthiazoline-6-sulphate) (ABTS) using xanthine oxidase, uricase and peroxidase is described and statistically examined through its application to normal and pathological sera. The method is very sensitive, precise (CV below 8.13%) and linear up to 152.5 U/l. Comparison with the methods of Hue & Free ((1965) Clin. Chem. 11, 708-715), and Giusti ((1974) In: Methods of Enzymatic Analysis, Bergmeyer, H. U., ed., p. 1086), and Ito et al. ((1981) Clin. Chim. Acta 115, 135-144) gave a good correlation (r greater than or equal to 0.969). The reference values for the ABTS-method are 2.93 to 23.92 U/l (mean = 13.57 U/l, CV = 22.43%). The mean values of guanase activities determined in sera of patients with different liver diseases (mean = 30.29 U/l), or chronic alcoholics (mean = 35.41 U/l) were significantly higher than normal. The patients with chronic diseases had significantly lower activity (mean = 7.22 U/l, t = 9.25, p less than 0.001).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The steady-state kinetics of peroxidase with 2,2'-azino-di-(3-ethyl-benzthiazoline-6-sulphonic acid) as chromogen.

The chemical nature of the important new chromogen ABTS [2,2'-azino-di-(3-ethyl-benzthiazoline-6-sulphonic acid)] is described together with an account of the redox and spectroscopic properties of the system ABTS--H2O2--peroxidase. Keq. is calculated and a study of the steady-state kinetics over a whole range of substrate concentrations is reported. By using novel methods of kinetic analysis, a...

متن کامل

Colorimetry of hemoglobin in plasma with 2,2'-azino-di(3-ethylbenzthiazoline-6-sulfonic acid) (ABTS).

Hemoglobin in plasma can be determined by the color-developing action of 2,2'-azino-di(3-ethylbenzthiazoline-6-sulfonic acid), which is oxidized to a colored form by a peroxidase-like effect of hemoglobin in the presence of hydrogen peroxide. Sensitivity, precision, and accuracy are discussed. The calibration curve is linear for hemoglobin concentrations up to 1 g/L; the minimum detectable conc...

متن کامل

Antioxidant Activity, β-Glucan and Lipid Contents of Oat Varieties

Brindzová L., Čertík M., Rapta P., Zalibera M., Mikulajová A., Takácsová M. (2008): Antioxidant activity, β-glucan and lipid contents of oat varieties. Czech J. Food Sci., 26: 163–173. The antioxidant activity, total phenolic and β-glucans contents, and the fatty acid profile of total lipids in covered (black and yellow) and naked oats were studied. Oats with black hulls showed a significantly ...

متن کامل

Efficient Assay for Total Antioxidant Capacity in Human Plasma Using a 96-Well Microplate

In the present study, we tried to establish an efficient assay for total antioxidant capacity (TAC) in human plasma using a 96-well microplate. TAC was assessed using lag time by antioxidants against the myoglobin-induced oxidation of 2,2'-azino-di(3-ethylbenzthiazoline-6-sulfonic acid (ABTS) with hydrogen peroxide, and expressed as Trolox equivalent. The linearity of the calibration curve with...

متن کامل

Protective effects of Koelreuteria paniculata Laxm. on oxidative stress and hydrogen peroxide-induced DNA damage

In this study, n-butanol fraction (KBF) and aqueous fraction (KAF) isolated from methanol extract of Koelreuteria paniculata Laxm. leaves were evaluated for their antioxidant potential using (ABTS) 2, 2-Azino-bis-(3-ethylbenzthiazoline-6-sulfonic acid), DPPH (2,2-diphenyl-2-picrylhydrazyl) assay, Reducing power assay and Superoxide anion radical scavenging assay. These fractions were also studi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie

دوره 24 6  شماره 

صفحات  -

تاریخ انتشار 1986