A comparison of a traditional endotracheal tube versus ETView SL in endotracheal intubation during different emergency conditions

نویسندگان

  • Zenon Truszewski
  • Paweł Krajewski
  • Marcin Fudalej
  • Jacek Smereka
  • Michael Frass
  • Oliver Robak
  • Bianka Nguyen
  • Kurt Ruetzler
  • Lukasz Szarpak
چکیده

BACKGROUND Airway management is a crucial skill essential to paramedics and personnel working in Emergency Medical Services and Emergency Departments: Lack of practice, a difficult airway, or a trauma situation may limit the ability of paramedics to perform direct laryngoscopy during cardiopulmonary resuscitation. Videoscope devices are alternatives for airway management in these situations. The ETView VivaSight SL (ETView; ETView Ltd., Misgav, Israel) is a new, single-lumen airway tube with an integrated high-resolution imaging camera. To assess if the ETView VivaSight SL can be a superior alternative to a standard endotracheal tube for intubation in an adult cadaver model, both during and without simulated CPR. METHODS ETView VivaSight SL tube was investigated via an interventional, randomized, crossover, cadaver study. A total of 52 paramedics participated in the intubation of human cadavers in three different scenarios: a normal airway at rest without concomitant chest compression (CC) (scenario A), a normal airway with uninterrupted CC (scenario B) and manual in-line stabilization (scenario C). Time and rate of success for intubation, the glottic view scale, and ease-of-use of ETView vs. sETT intubation were assessed for each emergency scenario. RESULTS The median time to intubation using ETView vs. sETT was compared for each of the aforementioned scenarios. For scenario A, time to first ventilation was achieved fastest for ETView, 19.5 [IQR, 16.5-22] sec, when compared to that of sETT at 21.5 [IQR, 20-25] sec (p = .013). In scenario B, the time for intubation using ETView was 21 [IQR, 18.5-24.5] sec (p < .001) and sETT was 27 [IQR, 24.5-31.5] sec. Time to first ventilation for scenario C was 23.5 [IQR, 19-25.5] sec for the ETView and 42.5 [IQR, 35-49.5] sec for sETT. CONCLUSIONS In normal airways and situations with continuous chest compressions, the success rate for intubation of cadavers and the time to ventilation were improved with the ETView. The time to glottis view, tube insertion, and cuff block were all found to be shorter with the ETView. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT02733536.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the ETView Single Lumen and Macintosh laryngoscopes for endotracheal intubation in an airway manikin with immobilized cervical spine by novice paramedics

CONTEXT Management of the airway of a trauma victim is considered challenging. Various approaches have been described to achieve airway control in this setup; many of them include video-assited viewing of the larynx during intubation. ETView Single Lumen (SL) is a novice single-use endotracheal tube equiped with a video camera and a light source at its distal tip. Its use was previously describ...

متن کامل

Can the ETView VivaSight SL Rival Conventional Intubation Using the Macintosh Laryngoscope During Adult Resuscitation by Novice Physicians?

UNLABELLED The aim of this study was to assess the performance of the ETView VivaSight SL (ETView) single-lumen airway tube with an integrated high-resolution imaging camera in a manikin-simulated cardiopulmonary resuscitation scenario with and without chest compression. This was a randomized crossover manikin trial. Following a brief training session, 107 volunteer novice physicians who were i...

متن کامل

Use of ETView Tracheoscopic Ventilation Tube® in airway management of a patient with tracheal injury.

I tracheobronchial injuries are fatal complications requiring immediate diagnosis and treatment. Unintentional one sided intubation, endotracheal tube cuff over-inflation, direct trauma with guides or boogie’s, double-lumen tube employment, tube replacement without cuff deflation and coughing against closed or blocked ventilation circuits are the possible causes.1, 2 Emergency or difficult intu...

متن کامل

Comparison of tracheal tube cuff inflation pressure among anesthesia team with different gradual level

Background & Objectives: Tracheal intubation is frequently performed in operating room. Over inflation of the endotracheal tube cuff is a risk factor for tracheal ischemia and subsequent complications. On the other hand inadequate cuff pressure increases the risk of aspiration of gastric contents. In this study, the endotracheal tube cuff pressure filled by the anesthesia team has been compared...

متن کامل

Common Complications of Endotracheal Intubation in Newborns

Objective The purpose of this study was to assess the frequency of complications of endotracheal intubation (ETI) in neonates. Methods The newborns that were admitted and needed urgent or semi-urgent intubation were enrolled in this study over a 1 year period. Route for intubation in all cases were orotracheal. Cases were not routinely sedated or paralyzed. The patients were clinically and rad...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 95  شماره 

صفحات  -

تاریخ انتشار 2016