Spatial variability in cortex-muscle coherence investigated with magnetoencephalography and high-density surface electromyography.

نویسندگان

  • Harri Piitulainen
  • Alberto Botter
  • Mathieu Bourguignon
  • Veikko Jousmäki
  • Riitta Hari
چکیده

Cortex-muscle coherence (CMC) reflects coupling between magnetoencephalography (MEG) and surface electromyography (sEMG), being strongest during isometric contraction but absent, for unknown reasons, in some individuals. We used a novel nonmagnetic high-density sEMG (HD-sEMG) electrode grid (36 mm × 12 mm; 60 electrodes separated by 3 mm) to study effects of sEMG recording site, electrode derivation, and rectification on the strength of CMC. Monopolar sEMG from right thenar and 306-channel whole-scalp MEG were recorded from 14 subjects during 4-min isometric thumb abduction. CMC was computed for 60 monopolar, 55 bipolar, and 32 Laplacian HD-sEMG derivations, and two derivations were computed to mimic "macroscopic" monopolar and bipolar sEMG (electrode diameter 9 mm; interelectrode distance 21 mm). With unrectified sEMG, 12 subjects showed statistically significant CMC in 91-95% of the HD-sEMG channels, with maximum coherence at ∼25 Hz. CMC was about a fifth stronger for monopolar than bipolar and Laplacian derivations. Monopolar derivations resulted in most uniform CMC distributions across the thenar and in tightest cortical source clusters in the left rolandic hand area. CMC was 19-27% stronger for HD-sEMG than for "macroscopic" monopolar or bipolar derivations. EMG rectification reduced the CMC peak by a quarter, resulted in a more uniformly distributed CMC across the thenar, and provided more tightly clustered cortical sources than unrectifed sEMGs. Moreover, it revealed CMC at ∼12 Hz. We conclude that HD-sEMG, especially with monopolar derivation, can facilitate detection of CMC and that individual muscle anatomy cannot explain the high interindividual CMC variability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spatial variability in cortex – muscle coherence investigated with magnetoencephalography 1 and high - density surface electromyography 2

19 Cortex–muscle coherence (CMC) reflects coupling between magnetoencephalography (MEG) 20 and surface electromyography (sEMG), being strongest during isometric contraction, but absent, 21 for unknown reasons, in some individuals. 22 We used a novel non-magnetic high-density sEMG (HD-sEMG) electrode grid (36 mm x 12 23 mm; 60 electrodes separated by 3 mm) to study effects of sEMG recording site...

متن کامل

High-density surface electromyography improves the identification of oscillatory synaptic inputs to motoneurons.

Many studies have addressed corticomuscular coherence (CMC), but broad applications are limited by low coherence values and the variability across subjects and recordings. Here, we investigated how the use of high-density surface electromyography (HDsEMG) can improve the detection of CMC. Sixteen healthy subjects performed isometric contractions at six low-force levels using a pinch-grip, while...

متن کامل

Localization of cortico-peripheral coherence with electroencephalography

BACKGROUND The analysis of coherent networks from continuous recordings of neural activity with functional MRI or magnetoencephalography has provided important new insights into brain physiology and pathology. Here we assess whether valid localizations of coherent cortical networks can also be obtained from high-resolution electroencephalography (EEG) recordings. METHODS EEG was recorded from...

متن کامل

Imaging the human motor system's beta-band synchronization during isometric contraction

Rhythmic synchronization likely subserves interactions among neuronal groups. One of the best studied rhythmic synchronization phenomena in the human nervous system is the beta-band (15-30 Hz) synchronization in the motor system. In this study, we imaged structures across the human brain that are synchronized to the motor system's beta rhythm. We recorded whole-head magnetoencephalograms (MEG) ...

متن کامل

Spatial variability of muscle activity during human walking: the effects of different EMG normalization approaches.

Human leg muscles are often activated inhomogeneously, e.g. in standing. This may also occur in complex tasks like walking. Thus, bipolar surface electromyography (sEMG) may not accurately represent whole muscle activity. This study used 64-electrode high-density sEMG (HD-sEMG) to examine spatial variability of lateral gastrocnemius (LG) muscle activity during the stance phase of walking, maxim...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neurophysiology

دوره 114 5  شماره 

صفحات  -

تاریخ انتشار 2015