Adequacy of ovarian diathermy under ultrasound control: an experimental model

نویسندگان

  • Anita Mylius Pimentel
  • Lucia Maria Kliemann
  • Daniela dos Santos Brum
  • Fábio Gallas Leivas
  • Paulo Roberto Stefani Sanches
  • Edison Capp
  • Helena von Eye Corleta
چکیده

BACKGROUND To develop a minimally invasive ovarian cauterization technique under transvaginal ultrasound control and evaluate the safety and feasability of monopolar cauterization to cause ovarian injury using female cattle of reproductive age as an experimental model. METHOD Experimental study in a university research center was performed. Eleven female bovines of reproductive age were submitted to monopolar transvaginal ovarian cauterization. The right ovary (RO) was punctured at four sites and 40 W was applied for 5 s at each point, resulting in a total of 800 J (Joules) of thermal energy. In the left ovary (LO), the procedure was similar, with the same time and 80 W, resulting in a thermal energy of 1600 J. Macroscopic and microscopic lesions were assessed. RESULTS Of 22 ovaries punctured, 20 were cauterized and exhibited macroscopic and typical microscopic lesions. No lesions could be found in the needle path. The measures of the areas of microscopic electrocautery lesions calculated estimating a cylindrical volume showed a median of 1.12% in the right ovary and 1.65% in the left ovary. When the estimate was calculated by spherical shape, the medians were 1.77% in the right ovary and 3.06% in the left ovary. There was a statistically significant difference in these two estimates (sphere, p = 0.008; cylinder, p = 0.021). CONCLUSION The experimental animal model described for transvaginal ultrasound-guided ovarian needle cauterization seems to be feasible. The ovaries were successfully cauterized without injuries in needle path and more energy resulted in significantly more thermal lesion. The safety and effectiveness of this technique, theoretically less invasive than current ovarian drilling methods, could be tested in anovulatory women with PCOS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transvaginal ultrasound ovarian diathermy: sheep as an experimental model

BACKGROUND Some techniques of transvaginal ovarian drilling have been previously described. Nevertheless a monopolar transvaginal ovarian cauterization, that use the expertise and safety of transvaginal puncture for oocyte captation seems to be an easier and feasible approach. The aim of this study was to develop a minimally invasive ovarian cauterization technique under transvaginal ultrasound...

متن کامل

The Local Effects of Ovarian Diathermy in an Ovine Model of Polycystic Ovary Syndrome

In order to develop a medical alternative to surgical ovarian diathermy (OD) in polycystic ovary syndrome (PCOS) more mechanistic information is required about OD. We therefore studied the cellular, molecular and vascular effects of diathermy on the ovary using an established ovine model of PCOS. Pregnant sheep were treated twice weekly with testosterone propionate (100 mg) from day 30-100 gest...

متن کامل

بررسی فراصوت درمانی بر ذخیره فولیکولی و رگزایی بافت تخمدان موش، 14 روز پس از پیوند هتروتوپیک

Introduction: One of the challenges facing ovarian transplantation is overcoming the ischemia/ reperfusion injury. When blood supply to the implanted tissue is suboptimal (immediate post implant period), ultrasound therapy has been shown to increase mass transport. The aim of this study was to investigate the effect of ultrasound on heterotopic transplantation of mouse ovarian tissue. Methods...

متن کامل

Laparoscopic Surgery for Ovarian Pregnancy using Diathermy Hook with Conservation of Ovary: A Case Report and Literature Review

A 31-year-old woman presented with a 7-week history of irregular vaginal bleeding without abdominal pain. She had been using the intrauterine contraceptive device (IUD) for the last 3 years. A pregnancy test was positive and subsequent serum beta human chorionic gonadotropin (β-HCG) was 4992 mIU/mL. A transvaginal ultrasound scan demonstrated an empty uterus with an associated adnexal mass but ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2013