Particulate Fouling and its Effect on U-Tube Steam Generator Thermal Performance
نویسندگان
چکیده
A multiple-node SIMULINK model of a U-tube steam generator (UTSG) has been developed so as to simulate the UTSG dynamics or responses to various defects, including fouling. UTSG responses to different events, such as reduced heat transfer area, change in heat transfer coefficient at different axial nodes, change in tube material conductivity, and the change of steam valve coefficients have been studied using the SIMULINK model. Then a mathematical model is established and implemented on MATLAB based on a systematic literature review on steam generator and heat exchanger fouling. Finally, the fouling model and the UTSG-SIMULINK model are both used to study the progress of tube fouling and the effects on UTSG thermal performance. The simulation results show the validity of the developed models. The developed models can be used to predict the degradation of UTSG thermal performance and hence provide guidance for plant maintenance planning. They can also be used to generate data for UTSG fault diagnosis. The results of these studies on the various defects and their effect on steam generator thermal performance are described.
منابع مشابه
Modeling and thermal parametric analysis of U-pipe evacuated tube solar collector for four different climates in Iran
In this study, thermal performance of the collector with analytic and quasi-dynamic method is evaluated based on energy balance equations for each part of the U-pipe evacuated tube solar collector. Using this approach, effect of different parameters such as tube size, overall heat loss coefficient, absorber tube absorptivity, mass flow rate and air layer thermal resistance on thermal performanc...
متن کاملPreparation and Characterization of CA−PEG−TiO2 Membranes: Effect of PEG and TiO2 on Morphology, Flux and Fouling Performance
Modified cellulose acetate (CA) membranes were prepared by dissolving the polymers in a mixture of acetone (AC) and N, N dimethylacetamide (DMAc) (70:30) solvent and deionized (DI) water was used in the coagulation bath. The introduction of polyethylene glycol (PEG) additive and TiO2 nanoparticles (NPs) into the casting solution has changed the structures of the resulting membranes during the p...
متن کاملSlagging and Fouling Characteristics of HRSG for Ferrosilicon Electric Furnaces
The slagging and fouling characteristics of the heat recovery steam generator (HRSG) for ferrosilicon electric furnaces are discussed in this paper. Three ash samples were taken from the HRSG of a ferrosilicon furnace in Ningxia Province, China, which suffered from serious slagging and fouling. X-ray fluorescence (XRF), X-ray powder diffraction (XRD) and scanning electron microscope (SEM) were ...
متن کاملFeasibility Study of Integrating Multi Effect Desalination and Gas Turbine Systems for Lavan Island Oil Refinery
In this research, feasibility study of integrating thermal desalination unit with Gas Turbine (GT) has been investigated using retrofit and grass root design techniques for Lavan Island Oil Refinery which is located in Persian Gulf. According to computed parameters on developed code for the power generation unit No.1 using EES (Engineering Equation Solver) software, thermal efficiency of t...
متن کاملExperimental investigation of thermal and electrical performances of a nanofluid-cooled photovoltaic/thermal system equipped with a sheet-and-grooved serpentine tube collector
Introduction: In the present experimental investigation, the thermal and electrical performances of a photovoltaic/thermal system equipped with a sheet-and-grooved serpentine tube collector are investigated. The water-magnetite nanofluid is used as the heat transfer fluid. The effect of nanoparticle volume concentration (0-1%), nanofluid mass flow rate (10-40 kg/h) and groove pitch (0, 0.54 an...
متن کامل