Fluoroimmunoassay of digitoxin in serum.
نویسندگان
چکیده
This fluoroimmunoassay for digitoxin in serum involves use of a sheep antiserum to digitoxin coupled to magnetizable solid-phase particles and fluorescein-labeled 3-O-succinyl digitoxigenin as tracer. Sodium salicylate blocks binding of the drug by binding proteins, and endogenous fluorophores and other interfering components in serum samples are reliably and completely removed at the separation and wash steps, which are facilitated by magnetic sedimentation. The method is sufficiently sensitive, precise, and specific for application to routine monitoring of digitoxin therapy, and results correlate closely (r = 0.992) with those of an established radioimmunoassay.
منابع مشابه
Some observations on serum concentrations of digitoxin and digoxin.
Serum concentrations of digitoxin and digoxin were measured in 145 cases with various heart diseases receiving maintenance doses of digitalis. Digitalis toxicity was seen in only 2 cases (1.4%). Day-to-day variation of serum concentration while taking the same daily dose was small in digitoxin therapy (13.8%), but a considerable variation was seen in digoxin therapy (24.4%). Serum concentration...
متن کاملSerum digitoxin concentrations in infants and children.
Serum digitoxin levels were measured in 18 infants (under two years) and in 23 children (aged 2-13 years) receiving maintenance therapy. Digitalization was carried out because of heart failure in 17 infants and 13 children and for control of dysrhythmia in one infant and 10 children. Mean maintenance dosage for infants was 0.0042 plus or minus 0.0008 (sd) mg/kg/day and for children was 0.0031 p...
متن کاملRadioimmunoassay Measurement of Serum Cardiac Glycoside Levels: Using Pharmacologic Principles to Solve Crossreactivity Problems
Laboratories performing analyses for serum cardiac glycosides are sometimes faced with the problem of distinguishing between digoxin and digitoxin in a specimen. The antibodies to the cardiac glycosides supplied with radioimmunoassay kits for these drugs have some measurable degree of cross reactivity. Therapeutic levels of digitoxin are approximately ten times greater than those of digoxin, an...
متن کاملMeasurement of Serum Cardiac Glycoside Levels: Using Pharmacologic Principles to Solve Crossreactivity Problems
Laboratories performing analyses for serum cardiac glycosides are sometimes faced with the problem of distinguishing between digoxin and digitoxin in a specimen. The antibodies to the cardiac glycosides supplied with radioimmunoassay kits for these drugs have some measurable degree of cross reactivity. Therapeutic levels of digitoxin are approximately ten times greater than those of digoxin, an...
متن کاملDigitalis glycosides in serum, urine, and cerebrospinal fluid, determined with a commercial radioimmunoassay.
We evaluated a commercial (Clinical Assays, Inc.) 125I radioimmunoassay for digitoxin for use in measuring cardiac glycosides in serum, buffer, urine, and cerebrospinal-fluid samples. We also assessed interference of seven cardioactive metabolites of digitoxin, including digoxin, with the assay. The precision of the assay was adequate for all matrixes studied for glycoside concentrations less t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 28 6 شماره
صفحات -
تاریخ انتشار 1982