Pseudotumor Caused by Titanium Particles From a Total Hip Prosthesis.
نویسندگان
چکیده
A 77-year-old woman underwent metal-on-polyethylene total hip arthroplasty for osteoarthritis of the right hip at another institution. During surgery, the greater trochanter was broken and internal fixation was performed with a trochanteric cable grip reattachment. Although postoperative recovery was uneventful, approximately 6 years later, the patient had severe right hip pain with apparent swelling, and she was referred to the authors' institution. Plain radiographs showed evidence of severe osteolysis in the proximal femur and cable breakage; however, preoperative aspiration culture findings were negative for bacterial growth. Magnetic resonance imaging showed a well-circumscribed mass, presumed to be a pseudotumor. Serum cobalt and chromium levels were within normal limits, and the serum titanium level was high. During surgery, the mass was excised and removal of the cable system revealed a sharp deficit in the bare femoral stem. Gross surgical findings showed no obvious evidence of infection and no corrosion at the head-neck junction; therefore, all components were retained besides the cable system, which resulted in clinical recovery. All of the cultures from specimens were negative for bacterial growth, and histologic findings were compatible with a pseudotumor, such as histiocytes containing metal particles, abundant plasma cells, and CD8-positive cells. Quantitative analysis by inductively coupled plasma atomic emission spectrometry showed that the main source of metal debris in the pseudotumor was the femoral stem, which was made of titanium alloy, not the broken cable, which was made of cobalt-chromium alloy. The findings suggest that titanium particles can form symptomatic solid pseudotumors.
منابع مشابه
Aggressive granulomatosis after cementless total hip arthroplasty as a result of inflammatory reaction to metal debris: case report.
Massive osteolysis and granulomatous pseudotumor tissue reactions are long-term complications of total hip replacement. It is a condition of localized bone resorption in contact with prosthetic material. It is speculated to be a consequence of metal hypersensitivity or inflammatory reaction to excessive wear. Ten years after total cementless hip replacement (metal on polyethylene surface), a 70...
متن کاملWear particles and ions from cemented and uncemented titanium-based hip prostheses—A histological and chemical analysis of retrieval material
Wear debris-induced inflammation is considered to be the main cause for periprosthetic osteolysis in total hip replacements (THR). The objective of this retrieval study was to examine the tissue reactions and exposure to metal ions and wear particles in periprosthetic tissues and blood samples from patients with titanium (Ti)-based hip prostheses that were revised due to wear, osteolysis, and/o...
متن کاملبررسی میزان دقت الگوریتمهای سیستم طراحی درمان رادیوتراپی در پیشبینی دز پروتز مفصل ران با استفاده از شبیه سازی مونتکارلو
Abstract Background : Beam-hardening artifacts in CT image set of patient with a hip prosthesis cause difference between dose distributions resulted by treatment planning system (TPS) algorithms and actual dose distribution in patient body. In this study, dose distributions of TPS algorithms were compared with the results of Monte Carlo simulations of Titanium and Steal as a h...
متن کاملSize of metallic and polyethylene debris particles in failed cemented total hip replacements.
Reports of differing failure rates of total hip prostheses made of various metals prompted us to measure the size of metallic and polyethylene particulate debris around failed cemented arthroplasties. We used an isolation method, in which metallic debris was extracted from the tissues, and a non-isolation method of routine preparation for light and electron microscopy. Specimens were taken from...
متن کاملA new strategy to reconstruct type III acetabular bone defect associated with inflammatory pseudotumor: combined medial and lateral acetabular bone grafting
RATIONALE Inflammatory pseudotumor has been commonly reported in patients undergoing total hip arthroplasty (THA). PATIENT CONCERNS We reported a patient who had a massive intra-pelvic pseudotumour and acetabular bone defect underwent two-stage revision THA. DIAGNOSES A new surgical strategy for pseudotumor after THA is performed. INTERVENTIONS Thorough debridement intra-pelvic pseudotumo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Orthopedics
دوره 39 1 شماره
صفحات -
تاریخ انتشار 2016