Ageing of Cadmium Telluride Radiation Detectors and Its Diagnostics with Low Frequency Noise

نویسندگان

  • Alexey Andreev
  • Ondrej Sik
  • Lubomir Grmela
  • Josef Sikula
چکیده

Samples of CdTe single crystals which are used as radiation detectors were periodically measured during a long time interval with different values of an applied voltage. The samples were also periodically exposed during long time periods to high temperatures of 390 K and to rapid changes of temperature from 300 K to 390 K. After 1.5 years of measurements we observed ageing of the samples which resulted in deterioration of their transport characteristics. The resistance of the samples increased significantly and current-voltage characteristics were unstable in time. Noise spectroscopy showed that low frequency noise can be used for detection of CdTe sample ageing as its spectral density increases significantly comparing to the 1/f noise of a high quality sample.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Low-Noise Free-Running High-Rate Photon-Counting for Space Communication and Ranging

We present performance data for low-noise free-running high-rate photon counting method for space optical communication and ranging. NASA GSFC is testing the performance of two types of novel photon-counting detectors 1) a 2x8 mercury cadmium telluride (HgCdTe) avalanche array made by DRS Inc., and a 2) a commercial 2880-element silicon avalanche photodiode (APD) array. We successfully measured...

متن کامل

Monte Carlo and least-squares methods applied in unfolding of X-ray spectra measured with cadmium telluride detectors

Spectra of calibration sources and X-ray beams were measured with a cadmium telluride (CdTe) detector. The response function of the detector was simulated using the GEANT4 Monte Carlo toolkit. Trapping of charge carriers were taken into account using the Hecht equation in the active zone of the CdTe crystal associated with a continuous function to produce drop of charge collection efficiency ne...

متن کامل

Effects of Dislocation Walls on Charge Carrier Transport Properties in CdTe Single Crystal

Radiation detectors for medical imaging at room temperature have been developed thanks to the availability of large chlorine-doped cadmium telluride (CdTe:Cl) crystals. Microstructural defects affect the performance of CdTe:Cl radiation detectors. Advanced characterization tools, such as Ion Beam Induced Current (IBIC) measurements and chemical etching on tellurium and cadmium faces were used t...

متن کامل

ION BEAM INDUCED CHARGE COLLECTION (IBICC) STUDIES OF CADMIUM ZINC TELLURIDE (CZT) RADIATION DETECTORS1 B.L.Doyle, G.Vizkelethy2, and D. S.Walsh

Cadmium Zinc Telluride is an emerging material for room temperature radiation detectors. In order to optimize the performance of these detectors, it is important to determine how the electronic properties of CZT are related to the presence of impurities and defects , that are introduced during the crystal growth and detector fabrication. At the Sandia microbeam facility IBICC and Time Resolved ...

متن کامل

Novel photon-counting detectors for free-space communication

We present performance data for novel photon-counting detectors for free space optical communication. NASA GSFC is testing the performance of two types of novel photon-counting detectors 1) a 2x8 mercury cadmium telluride (HgCdTe) avalanche array made by DRS Inc., and a 2) a commercial 2880-element silicon avalanche photodiode (APD) array. We present and compare dark count, photon-detection eff...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013