An automated procedure for photometric titration of red wine and associated instrumentation is described. The procedure was based on the flow-batch approach implemented employing multicommutation. The photometric detection was carried out using a homemade LED-based photometer. The mixing device, LED, and photodetector were attached to the titration chamber in order to form a compact and small-sized unit. The flow system comprised an automatic injector and three-way solenoid valves, which were controlled by a microcomputer through an electronic interface card. The software, written in Quick BASIC 4.5, was designed with abilities to accomplish all steps of the titration procedure including data acquisition and real-time processing to decide about the course of titration in the following step and so forth, until the titration endpoint was reached. The usefulness of the proposed titration system was demonstrated by analyzing red wine samples. When results were compared with those obtained using the AOAC reference method, no significant difference was observed at the 95% confidence level. A relative standard deviation of ca 2% (n=9) was obtained when processing a typical red wine sample containing 7.3 gl-1 total acidity expressed as tartaric acid.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Automated Multicommuted Flow Analysis Procedure for Photometric Determination of Reducing Sugars in Wine Employing a Directly Heated Flow‐Batch Device

This work presents an automated analytical procedure for the photometric determination of reducing sugars in wines. The procedure is based on the reaction of reducing sugars with potassium hexacyanoferrate(III) in an alkaline medium, and was implemented employing a multicommuted flow analysis (MCFA) approach. Sample heating to promote the reaction was accomplished using a flow-batch device, whi...

متن کامل

A Full Automatic Device for Sampling Small Solution Volumes in Photometric Titration Procedure Based on Multicommuted Flow System

In this work, an automatic device to deliver titrant solution into a titration chamber with the ability to determine the dispensed volume of solution, with good precision independent of both elapsed time and flow rate, is proposed. A glass tube maintained at the vertical position was employed as a container for the titrant solution. Electronic devices were coupled to the glass tube in order to ...

متن کامل

An Environmental Friendly Procedure for Photometric Determination of Hypochlorite in Tap Water Employing a Miniaturized Multicommuted Flow Analysis Setup

A photometric procedure for the determination of ClO(-) in tap water employing a miniaturized multicommuted flow analysis setup and an LED-based photometer is described. The analytical procedure was implemented using leucocrystal violet (LCV; 4,4',4''-methylidynetris (N,N-dimethylaniline), C(25)H(31)N(3)) as a chromogenic reagent. Solenoid micropumps employed for solutions propelling were assem...

متن کامل

A Highly Sensitive Multicommuted Flow Analysis Procedure for Photometric Determination of Molybdenum in Plant Materials without a Solvent Extraction Step

A highly sensitive analytical procedure for photometric determination of molybdenum in plant materials was developed and validated. This procedure is based on the reaction of Mo(V) with thiocyanate ions (SCN-) in acidic medium to form a compound that can be monitored at 474 nm and was implemented employing a multicommuted flow analysis setup. Photometric detection was performed using an LED-bas...

متن کامل

Simultaneous determination of tartaric acid and potassium in wines using a multicommuted flow system with dialysis.

A multicommuted flow system with the propulsion device placed before detection is proposed for the determination of tartaric acid and free potassium in table and Port wines. A dialysis unit was introduced to increase sample dilution and minimize matrix interferences. The determination of tartaric acid was based on the spectrophotometric monitorization of the complex formed by the dialyzed analy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of Automated Methods & Management in Chemistry

دوره 2006  شماره 

صفحات  -

تاریخ انتشار 2006