Is uterine depth measurement by trans-vaginal ultrasound alone as accurate as measurement carried out by trans-abdominal ultrasound-guided trial transfer?

نویسنده

  • Fawaz E. Edris
چکیده

OBJECTIVES To assess the reliability of trans-vaginal-scan (TVS) in measuring the uterine depth (UD) in comparison with ultrasound-guided trial-transfer (UTT). METHODS This prospective study was conducted in 66 consecutive patients undergoing in-vitro fertilization and embryo transfer (IVF-ET). The study took place in a private IVF center in Jeddah, Saudi Arabia between November 2013 and January 2014. The patients underwent UD measurements using TVS and UTT, sequentially. All scans were performed by a single sonographer, and all UTT were carried out by a single physician who was blinded to the TVS measurement. RESULTS The median (95% confidence interval) UD measurement using the TVS method was 6.9 cm (5.0-12.5) and UTT was 7.1 cm (5.9-13.5), (p<0.0001). Fifteen patients (22.7%) had a difference of >1 cm between the 2 measurement modalities (group-B). When measured by UTT, 93.3% of patients in group-B had UD >/-8cm, compared with 9.8% of patients in group-A, (p<0.0001). Group-B had a significantly longer uterine cavity when measured by UTT (p<0.0001), and a trend towards significance when measured by TVS (p=0.055). The TVS measurements generally underestimated UD when compared with UTT. CONCLUSION Trans-vaginal-scan is less reliable than UTT and should not be used as a substitute. Larger sample-size studies involving different personnel, and equipment is needed. 

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Cross-Sectional Study Comparing the Use of Trans- Abdominal Verses Trans-Vaginal Ultra-Sonography in the Diagnosis of Ectopic Pregnancy

Background: Ectopic pregnancy, also called as tubal pregnancy, is one of the complications of pregnancy in which the extra-uterine implantation of embryo occurs. The diagnosis of ectopic pregnancy is based mainly on ultrasonography (USG). The aim of the study is to decide which approach (trans vaginal or trans abdominal) is better to diagnose the ectopic pregnancy. Methods: The study was conduc...

متن کامل

O-30: The Correlation between Myometrial Thickness and In Vitro Fertilization/ Intracyto- Plasmic Sperm Injection (IVF/ ICSI) Outcomes

Background O-30: The Correlation between Myometrial Thickness and In Vitro Fertilization/ Intracyto- Plasmic Sperm Injection (IVF/ ICSI) Outcomes MaterialsAndMethods In this prospective cohort study, 453 infertile women undergoing IVF-ET/ICSI cycles without any obvious pathology of uterine were enrolled. Trans-vaginal ultrasounds were conducted on days 2-4 of the cycle (menstrual phase) precedi...

متن کامل

I-32: Uterine Factors Are Important for Successful Embryo Transfer After IVF

Embryo transfer (ET) is the final and most crucial step of the IVF procedure, characterized by a close collaboration between the clinician and the embryologist. Several studies have shown improvement in clinical pregnancy rates resulting from a focus on different aspects of the gentle embryo transfer technique. Issues such as impact of physician’s experience, trial transfer, catheter type, embr...

متن کامل

Fetal gender prediction based on placental location throughout first trimester transabdominal ultrasound

Background: Awareness of fetal gender at primary stages of pregnancy is very important. Fetal sex determination can reveal pressing information regarding fetal health. One of the methods of determining gender in the first trimester is according to the location of placenta. . This study investigated the accuracy and sensitivity of this method with trans-abdominal ultrasound in determining the se...

متن کامل

Ultrasound-guided boost irradiation of tumor cavity after lumpectomy in breast cancer

Background:  After breast conserving surgery, most recurrences occur around the primary tumor site. This justifies the use of boost radiotherapy to the primary site of tumor. Surgical scar is not always a good surrogate for the location of the lumpectomy cavity. The aim of this study was to evaluate ultrasonic guidance for detection of the lumpectomy cavity after breast conserving surgery ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 35  شماره 

صفحات  -

تاریخ انتشار 2014