Cystatin C standardization decreases assay variation and improves assessment of glomerular filtration rate.

نویسندگان

  • Natalie Ebert
  • Pierre Delanaye
  • Michael Shlipak
  • Olga Jakob
  • Peter Martus
  • Jan Bartel
  • Jens Gaedeke
  • Markus van der Giet
  • Mirjam Schuchardt
  • Etienne Cavalier
  • Elke Schaeffner
چکیده

BACKGROUND Cystatin C is increasingly used in glomerular filtration rate (GFR) estimation equations. The dependence of cystatin C results upon the analytical method has been a major source of controversy. METHODS Cystatin C was measured with non-standardized turbidimetric Roche Generation 1 and standardized nephelometric Siemens assays in 3666 and additionally with standardized Roche Generation 2 and Siemens in 567 blood samples of the Berlin Initiative Study. Cystatin C-based GFR was assessed with CKD-EPIcys (Chronic Kidney Disease Epidemiology) and CAPA (Caucasian, Asian, Pediatric, Adult) equations and the impact of the assays on GFR estimation was determined. Equation performance compared to measured GFR was evaluated. RESULTS Concordance of Roche Gen2 and Siemens was high with median difference of 0.003 ± 0.13 mg/L (limits of agreement: -0.12 to 0.12) and Passing Bablok correlation was essentially perfect. Roche Gen1 assay showed worse concordance with Siemens: median difference was 0.08 ± 0.13 mg/L (limits of agreement: -0.18 to 0.34) and correlation was inferior. Mean difference (± SD) of estimated GFRCKD-EPIcys was 0 ± 4 mL/min/1.73 m(2) for Gen2 and Siemens compared to -5 ± 8 with Gen1. Performance of GFR estimating equations was not influenced by the choice of Siemens or Gen2 assays. CONCLUSIONS Standardization of Roche Gen2 assay improved accuracy of cystatin C measurement compared to Siemens. It suggests only negligible method bias and results in equal performance of both assays when estimating GFR indicating that successful calibration has led to major progress in cystatin C analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Serum Cystatin C and Creati-nine Levels to Evaluate Early Renal Function after Kidney Transplantation

Background: Accurate and rapid assessment of allograft function is essential in renal transplant recipients in order to detect allograft rejection and to monitor drug nephrotoxicity. We aimed to evaluate the usefulness of cystatin C as a marker of kidney allograft function in the early post-transplant period and to compare this value with that of conventional serum creatinine concentration. Met...

متن کامل

SERUM CYSTATIN C AS A NEW MARKER OF GLOMERULAR FILTRATION RATE (GFR)

Cystatin C is a 13 KD basic protein that is a member of the cystatin superfamily of cysteine protease inhibitors. The cystatin C gene seems to be a house keeping gene, which is compatible with a stable production rate of cystatin C by most cells. This protein is freely filtered through the glomerulus and almost completely reabsorbed and catabolized by proximal tubular cells. Because of the...

متن کامل

Comparative Assessment of Neutrophil Gelatinase-Associated Lipocalin (NGAL) and Cystatin C as Early Biomarkers for Early Detection of Renal Failure in Patients with Hypertension

Background: Hypertension is one the most common causes of chronic kidney disease (CKD). One of the major concerns in hypertensive patients is early detection of renal disorders. In the past, serum creatinine (Scr) concentration was used as a marker of kidney function, but it proffers a late reflection of reduced glomerular filtration rate. Cystatin C and neutrophil gelatinase-associated lipocal...

متن کامل

Biological variation of cystatin C: implications for the assessment of glomerular filtration rate.

To assess the inherent potential for detecting mild to moderate reductions in glomerular filtration rate, this study determined the biological variability of serum cystatin C and creatinine in 12 healthy subjects. After accounting for analytical variation, interindividual variance accounted for 93% and intraindividual variance accounted for 7% of serum creatinine biological variation. As such, ...

متن کامل

Developments in the assessment of glomerular filtration rate.

The assessment of the glomerular filtration rate (GFR) is the most commonly used test of renal function. The accepted reference procedure employs an exogenous clearance marker whilst the most popular test is that of serum or plasma creatinine. All of these tests have limitations, although the surrogate endogenous markers are the most practical. Cystatin C, a low molecular weight protein which c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinica chimica acta; international journal of clinical chemistry

دوره 456  شماره 

صفحات  -

تاریخ انتشار 2016