The significance of surface changes on retrieved femoral components after total knee replacement.

نویسندگان

  • A Lakdawala
  • S Todo
  • G Scott
چکیده

We investigated the changes in surface roughness of retrieved femoral components in 18 men and four women at revision knee surgery. The mean age at revision was 68.4 years and the mean period of implantation was for 55.6 months. Eighteen implants were retrieved for aseptic loosening and four for infection. The surface changes in the articulating areas were inspected visually and the roughness (Ra) analysed with a profilometer. Parallel scratching and burnishing were the two main forms of damage. The mean Ra measurements in the articulating areas showed no statistically significant difference when compared with those in a control area on either side of the patellar groove at the apex of the femoral flange. This suggests that it is not essential to revise a well-fixed and correctly aligned femoral component where the polished surface has become burnished or bears fine parallel scratches, if the revision is conducted solely for failure of the tibial component.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship between Femoral Intercondylar Notch Narrowing on Radiography and Anatomical and Histopathologic Integrity of Anterior Cruciate Ligament in Patients Undergoing Total Knee Replacement Surgery

Abstract Introduction: The presence of cruciate ligaments are very important for normal knee kinematics. Knee arthroplasty prostheses, in which these ligaments are maintained, have better kinematics. The aim of the present study was to investigate the association between femoral intercondylar notch narrowing in radiography and clinical and histopathologic integrity of anterior cruciate li...

متن کامل

Distal Femoral Valgus Cut Errors in Total Knee Replacement

The causes of malalignment in total knee arthroplasty can be categorized into three different groups; 1) Errors in bone cuts 2) Errors in implant fixations, and 3) The method of setting down the cutting guides (1). We would like to announce that more several distal femoral valgus cut errors may occur during total knee replacement.

متن کامل

Stress Fracture of the Lateral Femoral Condyle afterTotal Knee Arthroplasty

Background: This is to assess one of the rare complications after total knee replacement and to assess risk factors of failure.Methods: 11 patients with varus knee and an average age of 67 years underwent TKA between 2005 and 2013. All patients returned with a sudden sharp knee pain, disability to walk and significant decrease in ROM about 4 to 8 weeks after surgery. Radiographic examination re...

متن کامل

Total Knee Replacement Sizing: Shoe Size Is a Better Predictor for Implant Size than Body Height

Background: Various sizes of implants need to be available during surgery. The purpose of this paper is to comparebody height and shoe size with implant sizes in patients who underwent total knee replacement surgery to see whichbiomarker is a better predictor for preoperative planning to determine implant size.Methods: A total of 100 knees, belonging to 50 females and 50 males, were observed. P...

متن کامل

Cemented versus hydroxyapatite fixation of the femoral component of the Freeman-Samuelson total knee replacement: a radiostereometric analysis.

We have carried out a radiostereometric study of 50 patients (54 knees) with osteoarthritis of the knee who were randomly allocated to receive a cemented or a hydroxyapatite-coated femoral component for total knee replacement. The patients were also stratified to receive one of three types of articulating surface (standard, rotating platform, Freeman-Samuelson (FS)1000) all based on the Freeman...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 87 6  شماره 

صفحات  -

تاریخ انتشار 2005