A Contactless Electrochemical Impedance Measurement Method

نویسندگان

  • L.Yu
  • E. Pun
چکیده

We present the first demonstration of a passive, contactless method to interrogate electrochemical impedance (EI) via a microfabricated MEMS coil. EI measurement was achieved using the principle of reflected impedance between a pair of inductively coupled coils. Ionic concentration and electrolyte temperature were wirelessly transduced from measurement electrodes connected to a microfabricated coil in a flexible thin film substrate. This technique is widely applicable for resistive transduction and obviates the need for soldering discrete electronic components, microcontrollers, batteries, and bulky hermetic packaging. It also features low power consumption (~75 μW) and all biocompatible construction (only Au, Ti, and Parylene C), making it ideal for use in harsh or in vivo environments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contactless Conductivity Detection in Ceramic Technology for On-Chip Electrophoresis

A capacitively coupled contactless conductivity detector produced in Low Temperature Co-fired Ceramic (LTCC) technology for microchip capillary electrophoresis (CE) is reported in this work. Electrodes located outside the measurement channel are used to sense impedance variations caused by conductive ions. The application of LTCC in combination with contactless conductivity detection is very pr...

متن کامل

Application of Measurement Models to Impedance Spectroscopy II. Determination of the Stochastic Contribution to the Error Structure

Development of appropriate models for the interpretation of impedance spectra in terms of physical properties requires, in addition to insight into the chemistry and physics of the system, an understanding of the measurement error structure. The time-varying character of electrochemical systems has prevented experimental determination of the stochastic contribution to the error structure. A met...

متن کامل

Stress Corrosion Cracking Detection of Sensitized Stainless Steel 304 in Chloride Media by Using Electrochemical Impedance Spectroscopy (EIS)

Electrochemical impedance spectroscopy (EIS) was used to detect stress corrosion cracking (SCC) in stainless steel 304 alloy exposed to an aqueous environment at 120 °C. Stainless steel 304 alloy as u-bend was tested in the solution that contains 40 weight percent of magnesium chloride. U-bended samples were prepared according to ASTM G30. EIS measurements were always performed simultaneously o...

متن کامل

A Microcontroller-based Instrument for Prostheses Osseointegration Measurement by Electrochemical Impedance Spectroscopy

A method based on Electrochemical Impedance Spectroscopy (EIS) for the diagnosis of prosthesis osseointegration was proposed by the Authors in previous works [1]-[2]. In this paper, the design, the implementation, and the metrological characterization of a microcontroller-based prototype conceived as a stand alone instrument to be used for in-vivo clinical applications are presented. The prelim...

متن کامل

On the correct use of stepped-sine excitations for the measurement of time-varying bioimpedance.

Many electrochemical/bioelectrochemical systems are intrinsically nonstationary and are affected by time-dependent phenomena. The requirement of stationarity in the classical version of impedance spectroscopy appears to be in conflict with the essential properties of the object, therefore a post-experimental mathematical/analytical procedure is necessary for the reconstruction of the 'true' imp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016