Interference of volatile anaesthetics with infrared analysis of carbon dioxide and nitrous oxide tested in the Dräger Cicero EM using sevoflurane.
نویسندگان
چکیده
In theory, setting an infrared multi-gas analyser to measure a volatile anaesthetic different from that in the sampled gas mixture may cause interference with carbon dioxide and nitrous oxide readings. The theory was investigated during evaluation of the Dräger Cicero EM anaesthetic workstation for the Medical Devices Agency. Interference occurred as predicted, and was most pronounced when the vapour analyser of the Cicero EM was deliberately and erroneously set to measure isoflurane, but with sevoflurane present in the gas mixture. With 6% sevoflurane in the gas mixture, the carbon dioxide reading decreased from 5% to 3.6%, and the nitrous oxide reading increased from 0% to 8% although, as the apparent isoflurane reading was 9%, the Cicero EM would alert the operator to the problem. However, operators are encouraged to ensure that, when using gas analysers such as that incorporated into the Cicero EM, the analyser is set to measure the correct volatile anaesthetic (the Cicero EM does this automatically when a Vapor vaporizer is attached) and the breathing system does not contain any other volatile anaesthetic agents.
منابع مشابه
The effects of sevoflurane are similar to those of isoflurane on the neuromuscular block produced by vecuronium.
We have examined the interactions of 1 MAC of isoflurane and sevoflurane (and 66% nitrous oxide in oxygen) with vecuronium, using the EMG response of the abductor digiti minimi to train-of-four (TOF) stimulation of the ulnar nerve. We constructed dose-response curves for vecuronium in 54 patients. The curves for both isoflurane and sevoflurane had a significant leftward shift compared with that...
متن کاملNitrous oxide decreases shivering threshold in rabbits less than isoflurane.
BACKGROUND Comparable minimum alveolar concentration (MAC) fractions of volatile anaesthetics produce similar thermoregulatory impairment. Nitrous oxide, however, decreases the vasoconstriction threshold less than sevoflurane or isoflurane. We tested the hypothesis that nitrous oxide also decreases shivering threshold less than isoflurane alone or in combination. METHODS Twenty-four rabbits w...
متن کاملEffect of nitrous oxide on cerebrovascular reactivity to carbon dioxide in children during sevoflurane anaesthesia.
BACKGROUND Sevoflurane and nitrous oxide have intrinsic cerebral vasodilatory activity. To determine the effects of nitrous oxide on cerebrovascular reactivity to carbon dioxide (CCO(2)R) during sevoflurane anaesthesia in children, middle cerebral artery blood flow velocity (V(mca)) was measured over a range of end-tidal carbon dioxide concentrations (E'(CO(2))), using transcranial Doppler (TCD...
متن کاملTheoretical context-sensitive elimination times for inhalation anaesthetics.
BACKGROUND Context-sensitive times to 50%, 80%, and 90% elimination from the brain have been calculated for volatile anaesthetics. This does not represent complete recovery because there are important residual effects even at 90% elimination, and the effect of anaesthetic metabolism on the rate of elimination has not been considered. METHODS A physiologically based model of anaesthetic uptake...
متن کاملComparative study of the Sevoflurane Asorption Capacity on Carbon Media Impregnated with Titanium Oxide Nanoparticles
Introduction: Occupational exposure to sevoflurane as an anesthetic gases in hospitals, dental clinics and veterinary clinics has been reported in various studies. Considering the harmful effects of sevoflurane anesthetic gas on the health of exposed personnel such as reproductive, preterm delivery and fetal abnormalities and increased spontaneous abortion, it is necessary to remove them from t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 76 5 شماره
صفحات -
تاریخ انتشار 1996