The effect on mechanical axis deviation of femoral lengthening with an intramedullary telescopic nail.
نویسندگان
چکیده
Internal lengthening devices in the femur lengthen along the anatomical axis, potentially creating lateral shift of the mechanical axis. We aimed to determine whether femoral lengthening along the anatomical axis has an inadvertent effect on lower limb alignment. Isolated femoral lengthening using the Intramedullary Skeletal Kinetic Distractor was performed in 27 femora in 24 patients (mean age 32 years (16 to 57)). Patients who underwent simultaneous realignment procedures or concurrent tibial lengthening, or who developed mal- or nonunion, were excluded. Pre-operative and six-month post-operative radiographs were used to measure lower limb alignment. The mean lengthening achieved was 4.4 cm (1.5 to 8.0). In 26 of 27 limbs, the mechanical axis shifted laterally by a mean of 1.0 mm/cm of lengthening (0 to 3.5). In one femur that was initially in varus, a 3 mm medial shift occurred during a lengthening of 2.2 cm. In a normally aligned limb, intramedullary lengthening along the anatomical axis of the femur results in a lateral shift of the mechanical axis by approximately 1 mm for each 1 cm of lengthening.
منابع مشابه
Trigonometric analysis of the mechanical axis deviation induced by telescopic intramedullary femoral lengthening nails.
Femoral lengthening with intramedullary nails can create alterations in the mechanical axis of the limb. This is based on the relationship of the anatomic femur axis to the mechanical femur axis, which is typically 5-9 degrees valgus. We developed trigonometric formulas to calculate the predicted change, using the lengths of the tibia, femur, and whole limb; the amount of lengthening; and the a...
متن کاملPRECICE magnetically-driven, telescopic, intramedullary lengthening nail: pre-clinical testing and first 30 patients
Introduction: Femoral/tibial lengthening with a telescopic, magnetically-powered, intramedullary nail is an alternative to lengthening with external fixation. Methods: Pre-clinical testing was conducted of the PRECICE in a human cadaver. A retrospective review of the first 30 consecutive patients who underwent unilateral lengthening was also conducted. Nail accuracy was obtained by comparing th...
متن کاملFemoral lengthening with a motorized intramedullary nail
PURPOSE We assessed whether an intramedullary lengthening device would reduce the problems normally associated with the external fixation technique. We also wanted to determine whether it is a reliable construct for limb lengthening and deformity correction in the femur. PATIENTS AND METHODS We conducted a matched-pair comparison of 30 femoral lengthenings, 15 with a motorized intramedullary ...
متن کاملLimb Lengthening Using the PRECICETM Nail System: Complications and Results
BACKGROUND Three types of telescopic nails are mainly used for intramedullary limb lengthening nowadays. Despite some important advantages of this new technology (e.g. controlled distraction rate, not restricted availability, possibility to perform accordion maneuvers), few articles exist on clinical results and complications after lengthening with the PRECICETM nail (Ellipse, USA). OBJECTIVE...
متن کاملComparison of Outcome of Femoral Shaft Fracture Fixation with Intramedullary Nail in Elderly Patient and Patients Younger than 60 Years Old
Background: Although intramedullary nailing (IMN) is an established and accepted operative treatment for femoral shaft fracture in patients younger than 60, there is a lack of data on the results of this treatment on those over 60. The purpose of this study was to determine if the outcome of IMN for femoral shaft fracture in elderly patients is also acceptable. Particular challenges in this g...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 94 9 شماره
صفحات -
تاریخ انتشار 2012