Improvement in pump function with endocardial biventricular pacing increases with activation time at the left ventricular pacing site in failing canine hearts.

نویسندگان

  • Elliot J Howard
  • James W Covell
  • Lawrence J Mulligan
  • Andrew D McCulloch
  • Jeffrey H Omens
  • Roy C P Kerckhoffs
چکیده

Recently, attention has been focused on comparing left ventricular (LV) endocardial (ENDO) with epicardial (EPI) pacing for cardiac resynchronization therapy. However, the effects of ENDO and EPI lead placement at multiple sites have not been studied in failing hearts. We hypothesized that differences in the improvement of ventricular function due to ENDO vs. EPI pacing in dyssynchronous (DYSS) heart failure may depend on the position of the LV lead in relation to the original activation pattern. In six nonfailing and six failing dogs, electrical DYSS was created by atrioventricular sequential pacing of the right ventricular apex. ENDO was compared with EPI biventricular pacing at five LV sites. In failing hearts, increases in the maximum rate of LV pressure change (dP/dt; r = 0.64), ejection fraction (r = 0.49), and minimum dP/dt (r = 0.51), relative to DYSS, were positively correlated (P < 0.01) with activation time at the LV pacing site during ENDO but not EPI pacing. ENDO pacing at sites with longer activation delays led to greater improvements in hemodynamic parameters and was associated with an overall reduction in electrical DYSS compared with EPI pacing (P < 0.05). These findings were qualitatively similar for nonfailing hearts. Improvement in hemodynamic function increased with activation time at the LV pacing site during ENDO but not EPI pacing. At the anterolateral wall, end-systolic transmural function was greater with local ENDO compared with EPI pacing. ENDO pacing and intrinsic activation delay may have important implications for management of DYSS heart failure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Left ventricular endocardial pacing improves resynchronization therapy in canine left bundle-branch hearts.

BACKGROUND We investigated the benefits of the more physiological activation achieved by left ventricular (LV) endocardial pacing (ENDO) as compared with conventional epicardial (EPI) LV pacing in cardiac resynchronization therapy. METHODS AND RESULTS In 8 anesthetized dogs with experimental left bundle-branch block, pacing leads were positioned in the right atrium, right ventricle, and at 8 ...

متن کامل

Endocardial left ventricular pacing improves cardiac resynchronization therapy in chronic asynchronous infarction and heart failure models.

BACKGROUND Studies in canine hearts with acute left bundle branch block (LBBB) showed that endocardial left ventricular (LV) pacing improves the efficacy of cardiac resynchronization therapy (CRT) compared with conventional epicardial LV pacing. The present study explores the efficacy of endocardial CRT in more compromised hearts and the mechanisms of such beneficial effects. METHODS AND RESU...

متن کامل

Transseptal conduction as an important determinant for cardiac resynchronization therapy, as revealed by extensive electrical mapping in the dyssynchronous canine heart.

BACKGROUND Simple conceptual ideas about cardiac resynchronization therapy assume that biventricular (BiV) pacing results in collision of right and left ventricular (LV) pacing-derived wavefronts. However, this concept is contradicted by the minor reduction in QRS duration usually observed. We investigated the electric mechanisms of cardiac resynchronization therapy by performing detailed elect...

متن کامل

Electromechanical model of cardiac resynchronization in the dilated failing heart with left bundle branch block.

Experimental studies have shown that biventricular pacing can improve systolic function in the failing heart with bundle branch block. The goal of this study was to develop and validate a three-dimensional computational model of the dilated failing heart with left bundle branch block to investigate how biventricular pacing can improve systolic mechanical performance and synchrony. In an anatomi...

متن کامل

Biventricular pacing and transmural dispersion of the repolarization.

In 2003, Medina-Ravell et al. 1 published a study that suggested that biventricular pacing could be arrhythmogenic in a subset of patients because of the reversal of the normal endocardial-to-epicardial activation sequence by left-ventricular epicardial pacing. As epicardial action potentials are briefer than endocardial action potentials, transmural dispersion of the repolarization (TDR) is la...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 301 4  شماره 

صفحات  -

تاریخ انتشار 2011