ERRATA Calculated impact of higher-order monochromatic aberrations on retinal image quality in a population of human eyes: erratum

نویسندگان

  • Antonio Guirao
  • Jason Porter
  • David R. Williams
  • Ian G. Cox
چکیده

We calculated the impact of higher-order aberrations on retinal image quality and the magnitude of the visual benefit expected from their correction in a large population of human eyes. Wave aberrations for both eyes of 109 normal subjects and 4 keratoconic patients were measured for 3-, 4-, and 5.7-mm pupils with a Shack– Hartmann sensor. Retinal image quality was estimated by means of the modulation transfer function (MTF) in white light. The visual benefit was calculated as the ratio of the MTF when the monochromatic higherorder aberrations are corrected to the MTF corresponding to the best correction of defocus and astigmatism. On average, the impact of the higher-order aberrations for a 5.7-mm pupil in normal eyes is similar to an equivalent defocus of ;0.3 D. The average visual benefit for normal eyes at 16 c/deg is ;2.5 for a 5.7-mm pupil and is negligible for small pupils (1.25 for a 3-mm pupil). The benefit varies greatly among eyes, with some normal eyes showing almost no benefit and others a benefit higher than 4 at 16 c/deg across a 5.7-mm pupil. The benefit for keratoconic eyes is much larger. The benefit at 16 c/deg is 12 and 3 for 5.7and 3-mm pupils, respectively, averaged across four keratoconics. These theoretical benefits could be realized in normal viewing conditions but only under specific conditions. © 2002 Optical Society of America OCIS codes: 330.7310, 330.5370.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of age on peripheral ocular aberrations.

On-axis monochromatic higher-order aberrations increase with age. Few studies have been made of peripheral refraction along the horizontal meridian of older eyes, and none of their off-axis higher-order aberrations. We measured wave aberrations over the central 42 degrees x32 degrees visual field for a 5mm pupil in 10 young and 7 older emmetropes. Patterns of peripheral refraction were similar ...

متن کامل

Customized Correction of Wavefront Aberrations in Abnormal Human Eyes by Using a Phase Plate and a Customized Contact Lens

Wavefront aberrations in human eyes were measured with a Shack-Hartmann wavefront sensor. Based on the measured wavefront aberrations, customized optics, such as phase plates and a customized contact lens, were designed and fabricated to compensate for higher-order wavefront aberrations in human eyes. The fabricated customized optics could successfully correct higherorder aberrations in human e...

متن کامل

Optical properties of the mouse eye

The Shack-Hartmann wavefront sensor (SHWS) spots upon which ocular aberration measurements depend have poor quality in mice due to light reflected from multiple retinal layers. We have designed and implemented a SHWS that can favor light from a specific retinal layer and measured monochromatic aberrations in 20 eyes from 10 anesthetized C57BL/6J mice. Using this instrument, we show that mice ar...

متن کامل

Vision improvement by correcting higher-order aberrations with phase plates in normal eyes.

PURPOSE To psychophysically demonstrate vision improvement when correcting higher-order aberrations with phase plates in normal eyes. METHODS The wavefront aberrations of three nonsurgical normal eyes were measured with a Shack-Hartmann wavefront sensor. With these measured aberrations, phase plates were fabricated using a lathing technique. Theoretical improvement in retinal image quality wa...

متن کامل

A method to predict refractive errors from wave aberration data.

We explored the impact of the eye's higher-order aberrations on subjective refraction comparing two classes of methods for estimating refractive state, one based directly on the wave aberration defined in the pupil plane and another based on the retinal image plane. The method defined in the pupil plane chose the sphere and cylinder that either minimized the wave aberration root mean square or ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002