The point-spread function of fiber-coupled area detectors

نویسندگان

  • James M. Holton
  • Chris Nielsen
  • Kenneth A. Frankel
چکیده

The point-spread function (PSF) of a fiber-optic taper-coupled CCD area detector was measured over five decades of intensity using a 20 µm X-ray beam and ~2000-fold averaging. The `tails' of the PSF clearly revealed that it is neither Gaussian nor Lorentzian, but instead resembles the solid angle subtended by a pixel at a point source of light held a small distance (~27 µm) above the pixel plane. This converges to an inverse cube law far from the beam impact point. Further analysis revealed that the tails are dominated by the fiber-optic taper, with negligible contribution from the phosphor, suggesting that the PSF of all fiber-coupled CCD-type detectors is best described as a Moffat function.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Charge-coupled device area x-ray detectors

Charge-coupled device ~CCD! area x-ray detector technology is reviewed. CCD detectors consist of a serial chain of signal components, such as phosphors, fiber optics or lenses, image intensifiers and the CCD which serve to convert the x-ray energy to light or electron-hole pairs and to record the spatially resolved image. The various combinations of components that have been used to make CCD de...

متن کامل

مشاهده ی پرتوهای کیهانی با آرایه ی البرز 1

The first phase of the Alborz Observatory Array (Alborz-1) consists of 20 plastic scintillation detectors each one with surface area of 0.25  spread over an area of  realized to the study of Extensive Air Showers around the knee at the Sharif University of Technology campus. The first stage of the project including construction and operation of a prototype system has now been completed and the ...

متن کامل

The Influence of Crystal Size and Material on Intercrystal Scattering and Parallax in PET Block Detectors: A Monte Carlo Study

Introduction:  In  this  study,  we  utilized  the  MCNP4C  Monte  Carlo  code  to  quantitatively  evaluate  the  influence of crystal size and material on intercrystal scatter and parallax effects.   Materials and Methods:  For each of the 5 selected crystals (BGO, LSO, LYSO, LuAP, GSO), transport of  511  keV  photons  originating  from  a  point  source  and  incident  on  the  central  cry...

متن کامل

Coupled fixed point results for weakly related mappings in partially ordered metric spaces

In the present paper‎, ‎we show the existence of a coupled fixed point for a non-decreasing mapping in partially ordered complete metric space using a partial order induced by an appropriate function $phi$‎. ‎We also define the concept of weakly related mappings on an ordered space‎. ‎Moreover common coupled fixed points for two and three weakly related mappings are also proved in the same space‎.

متن کامل

Some local fixed point results under $C$-class functions with applications to coupled elliptic systems

The main objective of the paper is to state newly fixed point theorems for set-valued mappings in the framework of 0-complete partial metric spaces which speak about a location of a fixed point with respect to an initial value of the set-valued mapping by using some $C$-class functions. The results proved herein generalize, modify and unify some recent results of the existing literature. As an ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2012