Electro and gamma nuclear physics in Geant4
نویسندگان
چکیده
Adequate description of electro and gamma nuclear physics is of utmost importance in studies of electron beam-dumps and intense electron beam accelerators. I also is mandatory to describe neutron backgrounds and activation in linear colliders. This physics was elaborated in Geant4 over the last year, and now entered into the stage of practical application. In the Geant4 Photo-nuclear data base there are at present about 50 nuclei for which the Photo-nuclear absorption cross sections have been measured. Of these, data on 14 nuclei are used to parametrize the gamma nuclear reaction cross-section The resulting cross section is a complex, factorized function of A and e = log(Eγ), where Eγ is the energy of the incident photon. Electro-nuclear reactions are so closely connected with Photo-nuclear reactions that sometimes they are often called “Photo-nuclear”. The one-photon exchange mechanism dominates in Electro-nuclear reactions, and the electron can be substituted by a flux of photons. Folding this flux with the gamma-nuclear cross-section, we arrive at an acceptable description of the electro-nuclear physics. Final states in gamma and electro nuclear physics are described using chiral invariant phase-space decay at low gamma or equivalent photon energies, and quark gluon string model at high energies. We will present the modeling of this physics in Geant4, and show results from practical applications.
منابع مشابه
A Monte Carlo study of SPECT in boron neutron capture therapy for a heterogeneous human phantom
Background: Boron neutron capture therapy (BNCT) is a binary radiotherapy combining biochemical targeting with neutron irradiation. However, monitoring the boron distribution is a fundamental problem in BNCT. Prompt gamma rays emitted by boron capture reaction can be used to address the issue. Materials and Methods: The general-purpose Monte Carlo toolkits Geant4 and MCNP were used for the simu...
متن کاملDevelopment of a Phase Space Generator software for Medical Linear Accelerator Applications
Introduction: During the last decades, simulation of radiation therapy treatment conditions in treatment room for studying with more details in comparison with treatment planning system (TPS) is taken into consideration. The most problem with starting these kind of researches is the geometry of Medical linacs and verification of the accelerators. Therefore, researchers tried to...
متن کاملCALCULATION OF CROSS SECTION AND PRODUCTION YIELD OF RADIOPHARMACEUTICAL PRASEODYMIUM-139 THROUGH 140CE(P, 2N)139PR REACTION USING GEANT4 AND TALYS NUCLEAR CODES
Background & Aim: PET is a very useful and suitable imaging method in nuclear medicine. This method uses positrons with a special energy for imaging. The elements of the lanthanide are suitable for the decay of positrons with a specific energy for use in PET. Praseodymium-139 with a half-life of 4.5 hours is one of the useful elements in the group of lanthanides that can be used in PET. In this...
متن کاملThe Geant4 Object Oriented Simulation Toolkit
Geant4 is a toolkit for the simulation of the passage of particles through matter, developed with advanced software engineering techniques. Its application areas include high energy and nuclear physics experiments, space physics, medical physics and radiation background studies.
متن کاملEnhancing and verification of dose in external radiation therapy using Gd nanoparticles as a theranostic agent: A Monte Carlo simulation study
Introduction: Theranostics, in particular, the use of radionuclides with the capability of simultaneous imaging and treatment has opened new horizons in personalized treatment planning of targeted radiation therapy. In this approach, positive beta or gamma emitters are required for imaging and alpha, beta and Auger electrons for treatment purpose. On the other hand, studies hav...
متن کامل