The magnetic precursor of L1448-mm: excitation differences between ion and neutral fluids

نویسندگان

  • J. F. Roberts
  • I. Jiménez-Serra
  • J. Martín-Pintado
  • S. Viti
  • A. Rodríguez-Franco
  • A. Faure
  • J. Tennyson
چکیده

Context. Shock modelling predicts an electron density enhancement within the magnetic precursor of C-shocks. Previous observations of SiO, H13CO+, HN13C and H13CN toward the young L1448-mm outflow showed an over-excitation of the ion fluid that was attributed to an electron density enhancement in the precursor. Aims. We re-visit this interpretation and test if it still holds when we consider different source morphologies and kinetic temperatures for the observed molecules. To do this, we use updated collisional coefficients of HN13C and SiO with electrons in our excitation model. We also aim to give some insight on the spatial extent of the electron density enhancement around L1448-mm. Methods. We estimate the opacities of H13CO+ and HN13C by observing the J = 3 → 2 lines of rarer isotopologues. To model the excitation of the molecules, we use the large velocity gradient (LVG) approximation with updated collisional coefficients to i) re-analyse the observations toward the positions where the over-excitation of H13CO+ has previously been observed [i.e. toward L1448-mm at offsets (0, 0) and (0, –10)]; and ii) to investigate if the electron density enhancement is still required for the cases of extended and compact emission, and for kinetic temperatures of up to 400 K. We also report several lines of SiO, HN13C and H13CO+ toward new positions around this outflow, to investigate the spatial extent of the over-excitation of the ions in L1448-mm. Results. From the isotopologue observations, we find that the emission of H13CO+ and HN13C from the precursor is optically thin if this emission is extended. Using the new collisional coefficients, an electron density enhancement is still needed to explain the excitation of H13CO+ for extended emission and for gas temperatures of <∼400 K toward L1448-mm (0, –10), and possibly also toward L1448-mm (0, 0). For compact emission the data cannot be fitted. We do not find any evidence for the over-excitation of the ion fluid toward the newly observed positions around L1448-mm. Conclusions. The observed line emission of SiO, HCO and HNC toward L1448-mm (0, 0) and (0, –10) is consistent with an electron density enhancement in the precursor component, if this emission is spatially extended. This is also true for the case of high gas temperatures (<∼400 K) toward the (0, –10) offset. The electron density enhancement seems to be restricted to the southern, redshifted lobe of the L1448-mm outflow. Interferometric images of the line emission of these molecules are needed to confirm the spatial extent of the over-excitation of the ions and thus, of the electron density enhancement in the magnetic precursor of L1448-mm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On the Evolution of the Molecular Line Profiles Induced by the Propagation of C-shock Waves

We present the first results of the expected variations of the molecular line emission arising from material recently affected by C-shocks (shock precursors). Our parametric model of the structure of C-shocks has been coupled with a radiative transfer code to calculate the molecular excitation and line profiles of shock tracers such as SiO, and of ion and neutral molecules such as HCO and HNC, ...

متن کامل

Far infrared mapping of the gas cooling along the L 1448 outflow ?

The molecular outflows associated with the two Class 0 sources L1448-mm and L1448-IRS3 have been mapped with the spectrometers on board the ISO satellite allowing to study in detail the physical and chemical structure of the shocked gas. The far infrared cooling is mainly due to the emission from pure rotational lines of CO, H2O and H2 excited at temperatures between 500 and 1200 K. [O i]63μm e...

متن کامل

Warm SiO gas in molecular bullets associated with protostellar outflows

Context. In this paper we present the first SiO multiline analysis (from J=2-1 to J=11-10) of the molecular bullets along the outflows of the Class 0 sources L1448-mm and L1157-mm, obtained through observations with IRAM and JCMT. Aims. This analysis has been performed to investigate the physical properties of different types of bullets, in order to explore their excitation conditions and put c...

متن کامل

Parametrization of C-shocks. Evolution of the Sputtering of Grains

Context. The detection of a narrow SiO line emission toward the young shocks of the L1448-mm outflow has been interpreted as a signature of the magnetic precursor of C-shocks. In contrast with the very low SiO abundances (≤10−12) derived from the ambient gas, the narrow SiO emission in the precursor component at almost ambient velocities reveals enhanced SiO abundances of ∼10−11. This enhanceme...

متن کامل

Calculation of total dose and dose equivalent distribution in the treatment of lung cancer using MR-guided carbon therapy

Nowadays, in order to improve the accuracy of treatment in radiation therapy, there are many attempts to use magnetic resonance imaging (MRI) due to the advantages of excellent soft tissue contrast and ultra-fast pulse sequences. On the other hand, carbon-ion radiation therapy is developing rapidly due to the benefits of greater relative biological effectiveness (RBE) and the application in the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010