Noninvasive evaluation of the aortic root with multislice computed tomography implications for transcatheter aortic valve replacement.
نویسندگان
چکیده
OBJECTIVES In the present study, the anatomy of the aortic root was assessed noninvasively with multislice computed tomography (MSCT). BACKGROUND Transcatheter aortic valve replacement has been proposed as an alternative to surgery in high-risk patients with severe aortic stenosis. For this procedure, detailed knowledge of aortic annulus diameters and the relation between the annulus and the coronary arteries is needed. METHODS In 169 patients (111 men, age 54 +/- 11 years), a 64-slice MSCT scan was performed for evaluation of coronary artery disease. Of these, 150 patients had no or mild aortic stenosis, and 19 patients had moderate to severe aortic stenosis. Reconstructed coronal and sagittal views were used for assessment of the aortic annulus diameter in 2 directions. In addition, the distance between the annulus and the ostium of the right and left coronary arteries and the length of the coronary leaflets were assessed. The LV outflow tract and interventricular septum were analyzed on the single oblique sagittal view at end-diastole. RESULTS The diameter of the aortic annulus was 26.3 +/- 2.8 mm on the coronal view, and 23.5 +/- 2.7 mm on the sagittal view. Mean difference between the 2 diameters was 2.9 +/- 1.8 mm, indicating an oval shape of the aortic annulus. Mean distance between the aortic annulus and the ostium of the right coronary artery was 17.2 +/- 3.3 mm, and mean distance between the annulus and the ostium of the left coronary artery was 14.4 +/- 2.9 mm. In 82 patients (49%), the length of the left coronary leaflet exceeded the distance between the annulus and the ostium of the left coronary artery. There were no significant differences in the diameter of annulus, diameter of sinus of Valsalva, or the distance between the annulus, left coronary leaflet, and the ostium of the left coronary artery, between the patient with and without severe aortic stenosis. CONCLUSIONS The MSCT can provide detailed information on the shape of the aortic annulus and the relation between the annulus and the ostia of the coronary arteries. Thereby, MSCT may be helpful for avoiding paravalvular leakage and coronary occlusion and may facilitate the selection of candidates for transcatheter aortic valve replacement.
منابع مشابه
Is time of renal hypoperfusion an important variable in determining response to renal artery revascularization?
3. Gurvitch R, Webb JG, Yuan R, et al. Aortic annulus diameter determination by multidetector computed tomography: reproducibility, applicability, and implications for transcatheter aortic valve implantation. J Am Coll Cardiol Intv 2011;4:1235–45. 4. Achenbach S, Delgado V, Hausleiter J, Schoenhagen P, Min JK, Leipsic JA. SCCT expert consensus document on computed tomography imaging before tran...
متن کاملProsthesis oversizing in balloon-expandable transcatheter aortic valve implantation is associated with contained rupture of the aortic root.
BACKGROUND To retrospectively investigate the potential cause of contained rupture of the aortic root in balloon-expandable transcatheter aortic valve implantation (TAVI) by means of pre- and postinterventional multislice computed tomography. METHODS AND RESULTS Seventy-two patients (mean age 82±7 years, mean aortic valve area 0.69±0.19 cm(2)) underwent balloon-expandable TAVI using the Edwar...
متن کاملImaging to select and guide transcatheter aortic valve implantation.
Transcatheter aortic valve implantation (TAVI) is indicated for patients with severe aortic stenosis and high or prohibitive surgical risk. Patients' selection requires clinical and anatomical selection criteria, being the later determined by multimodality imaging evaluation. Echocardiography, multislice computed tomography (MSCT), angiography, and cardiovascular magnetic resonance (CMR) are th...
متن کاملTranscatheter aortic valve implantation operators - get involved in imaging!
Pre-procedural planning is the key element of transcatheter aortic valve implantation (TAVI). Multislice computed tomography of the chest, abdomen and pelvis with the ability to perform a 3-dimensional reconstruction has become the cornerstone of pre-procedural planning. We would like to encourage TAVI operators (interventional cardiologist and surgeons) to get involved in imaging. All TAVI ope...
متن کاملAcute myocardial ischemia after aortic valve replacement: a comprehensive diagnostic evaluation using dynamic multislice spiral computed tomography.
We describe the case of a 72-year-old man presenting with endocarditis and clinical signs of acute myocardial ischemia after biological aortic valve replacement. A comprehensive cardiac dynamic multislice spiral computed tomography demonstrated: (1) an endocarditic vegetation of the aortic valve; (2) a subvalvular leakage feeding a paravalvular pseudoaneurysm based on an aortic root abscess wit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- JACC. Cardiovascular imaging
دوره 1 3 شماره
صفحات -
تاریخ انتشار 2008