On stabilization of loosened hip stems via cement injection into osteolytic cavities.

نویسندگان

  • A Andreykiv
  • D Janssen
  • R G H H Nelissen
  • E R Valstar
چکیده

BACKGROUND Cement injection into osteolytic areas around the cement mantle is a technique for refixation of loose hip implants for patients who cannot undergo standard revision surgery. Preliminary clinical results show the improvement in walking distance, patients' independence and pain relief. METHODS In this study, we use a detailed finite element model to analyze whether cement injection into osteolytic areas contributes to the overall implant stability. We study the effect of various factors, like location and size of osteolytic areas, interface conditions and bone stiffness on bone-cement relative motion. FINDINGS Presented results demonstrate that the procedure is most effective for the osteolytic areas located in the proximal region of the femur, while factors like a thin layer of residual fibrous tissue around the injected cement, that was not removed during the surgery, combined with reduced bone stiffness reduce the efficiency of the procedure. INTERPRETATION Cement injection is able to stabilize loosened hip prostheses. However, it is important to remove the fibrous tissue layer completely, as even a thin layer will negatively influence stabilization. We will focus our research efforts on developing fibrous tissue removal techniques in order to optimize this minimally invasive treatment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stem subsidence of polished and rough double-taper stems

BACKGROUND AND PURPOSE Many clinical reports have indicated that polished hip stems show better clinical results than rough stems of the same geometry. It is still unknown, however, what the mechanical effects are of different surface finishes on the cement at the cement-bone interface. We compared mechanical effects in an in vitro cemented hip arthroplasty model. METHODS Two sizes of double-...

متن کامل

Gene therapy and cement injection for restabilization of loosened hip prostheses.

Loosening of orthopedic hip prostheses is an increasing health problem. In elderly patients with comorbidity,revision surgery may lead to high mortality rates. A less invasive surgical technique is therefore required to reduce these patient risks. To this end a percutaneous gene therapy approach was designed to destroy the periprosthetic loosening membrane, and enable refixing of the hip prosth...

متن کامل

Collarless polished tapered stem: clinical and radiological results at a minimum of ten years' follow-up.

We retrospectively reviewed 175 patients (191 hips) who had undergone primary cemented total hip replacement between November 1992 and November 1995 using a collarless polished double-tapered femoral component after a minimum of ten years (mean 11.08; 10 to 12.8). All stems were implanted using contemporary cementing techniques with a distal cement restrictor, pressurised lavage, retrograde cem...

متن کامل

Tissue reaction around loosened prostheses: a histological, X-ray microanalytic and immunological study.

Tissue reactions at the cement-bone and artificial implant-bone interface were examined light and electron microscopically in thirty-six patients who underwent revisory operation of hip or knee replacement. The reactions were classified into three types: inert tissue, active tissue with giant cell proliferation, and active tissue with predominant foamy cell proliferation. The third type of reac...

متن کامل

Primary total hip arthroplasty without the use of bone cement: a 10-year follow-up of 157 hips.

BACKGROUND The cementless fixation technique in total hip arthroplasty (THA) was developed to solve clinical problems such as aseptic loosening and osteolysis which were thought to be associated with the use of bone cement. This retrospective study reports our mid-term results with cementless THA. METHODS A series of 173 consecutive, unselected cementless THA procedures using the Omnifit pros...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical biomechanics

دوره 27 8  شماره 

صفحات  -

تاریخ انتشار 2012