Fosfomycin Addition to Poly(D,L-Lactide) Coating Does Not Affect Prophylaxis Efficacy in Rat Implant-Related Infection Model, But That of Gentamicin Does
نویسندگان
چکیده
Gentamicin is the preferred antimicrobial agent used in implant coating for the prevention of implant-related infections (IRI). However, the present heavy local and systemic administration of gentamicin can lead to increased resistance, which has made its future use uncertain, together with related preventive technologies. Fosfomycin is an alternative antimicrobial agent that lacks the cross-resistance presented by other classes of antibiotics. We evaluated the efficacy of prophylaxis of 10% fosfomycin-containing poly(D,L-lactide) (PDL) coated K-wires in a rat IRI model and compared it with uncoated (Control 1), PDL-coated (Control 2), and 10% gentamicin-containing PDL-coated groups with a single layer of coating. Stainless steel K-wires were implanted and methicillin-resistant Staphylococcus aureus (ATCC 43300) suspensions (103 CFU/10 μl) were injected into a cavity in the left tibiae. Thereafter, K-wires were removed and cultured in tryptic soy broth and then 5% sheep blood agar mediums. Sliced sections were removed from the tibiae, stained with hematoxylin-eosin, and semi-quantitatively evaluated with X-rays. The addition of fosfomycin into PDL did not affect the X-ray and histopathological evaluation scores; however, the addition of gentamicin lowered them. The addition of gentamicin showed a protective effect after the 28th day of X-ray evaluations. PDL-only coating provided no protection, while adding fosfomycin to PDL offered a 20% level protection and adding gentamicin offered 80%. Furthermore, there were 103 CFU level growths in the gentamicin-added group, while the other groups had 105. Thus, the addition of fosfomycin to PDL does not affect the efficacy of prophylaxis, but the addition of gentamicin does. We therefore do not advise the use of fosfomycin as a single antimicrobial agent in coating for IRI prophylaxis.
منابع مشابه
A biodegradable gentamicin-hydroxyapatite-coating for infection prophylaxis in cementless hip prostheses.
A degradable, poly (lactic-co-glycolic acid) (PLGA), gentamicin-loaded prophylactic coating for hydroxyapatite (HA)-coated cementless hip prostheses is developed with similar antibacterial efficacy as offered by gentamicin-loaded cements for fixing traditional, cemented prostheses in bone. We describe the development pathway, from in vitro investigation of antibiotic release and antibacterial p...
متن کاملPreparation of a reservoir type levonorgestrel delivery system using high molecular weight poly L-lactide
Implantable contraceptive is likely to be a promising new option for fertility control, as we have entered the twenty-first century and the world’s population grows by one billion people in a single decade. The main objective of this study was to develop a subdermal implant for levonorgestrol (a synthetic progestin from 19-norandrostanes) using a high molecular weight biodegradable polymer , i....
متن کاملImplant infections and antibiotic-impregnated silicone rubber coating.
A method is described for coating silicone rubber-encapsulated implant devices with an outer layer of silicone rubber impregnated with a mixture of gentamicin sulphate and diethanolamine fusidate. A coating of this sort provides bactericidal activity lasting for a few days in the film of fluid surrounding such an implant. When used for coating our implants, the retrospective rate of implant inf...
متن کاملDoes Propylthiouracil Increase the Gentamicin-Induced Nephrotoxicity In Rat?
Objective(s): The aim of this study was to evaluate the effect of subacute administration of propylthiouracil (PTU) on gentamicin (GM)-induced nephrotoxicity in male rats. Materials and Methods: Male Wistar rats were divided into 4 experimental groups as follow: (1) Control group: isotonic saline (1 ml/kg, IP. for 18 d), (2) GM group: 100 mg/kg, IP for 8 d, (3) PTU group: PTU...
متن کاملPreparation of a reservoir type levonorgestrel delivery system using high molecular weight poly L-lactide
Implantable contraceptive is likely to be a promising new option for fertility control, as we have entered the twenty-first century and the world’s population grows by one billion people in a single decade. The main objective of this study was to develop a subdermal implant for levonorgestrol (a synthetic progestin from 19-norandrostanes) using a high molecular weight biodegradable polymer , i....
متن کامل