Does an Antibiotic-Loaded Hydrogel Coating Reduce Early Post-Surgical Infection After Joint Arthroplasty?

نویسندگان

  • Carlo Luca Romanò
  • Kostantinos Malizos
  • Nicola Capuano
  • Riccardo Mezzoprete
  • Michele D'Arienzo
  • Catherine Van Der Straeten
  • Sara Scarponi
  • Lorenzo Drago
چکیده

Background: Infection remains among the main reasons for joint prosthesis failure. Preclinical reports have suggested that antibacterial coatings of implants may prevent bacterial adhesion and biofilm formation. This study presents the results of the first clinical trial on an antibiotic-loaded fast-resorbable hydrogel coating (Defensive Antibacterial Coating, DAC®) in patients undergoing hip or knee prosthesis. Methods: In this multicenter, randomized prospective study, a total of 380 patients, scheduled to undergo primary (n=270) or revision (n=110) total hip (N=298) or knee (N=82) joint replacement with a cementless or a hybrid implant, were randomly assigned, in six European orthopedic centers, to receive an implant either with the antibiotic-loaded DAC coating (treatment group) or without coating (control group). Pre- and postoperative assessment of clinical scores, wound healing, laboratory tests, and x-ray exams were performed at fixed time intervals. Results: Overall, 373 patients were available at a mean follow-up of 14.5 ± 5.5 months (range 6 to 24). On average, wound healing, laboratory and radiographic findings showed no significant difference between the two groups. Eleven early surgical site infections were observed in the control group and only one in the treatment group (6% vs. 0.6%; p=0.003). No local or systemic side effects related to the DAC hydrogel coating were observed, and no detectable interference with implant osteointegration was noted. Conclusions: The use of a fast-resorbable, antibiotic-loaded hydrogel implant coating can reduce the rate of early surgical site infections, without any detectable adverse events or side effects after hip or knee joint replacement with a cementless or hybrid implant.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Two-stage Total Knee Arthroplasty for Treatment of Surgical Failure of Septic Arthritis in Degenerative Knee Joints

Background: The ultimate goal of the treatment of infectious knee arthritis is to protect the articular cartilage fromadverse effects of infection. Treatment, however, is not always hundred percent successful and has a 12% failurerate. Persistent infection is more likely to happen in elderly patients and those with underlying joint diseases,particularly osteoarthritis. Eradica...

متن کامل

Does Implant Coating With Antibacterial-Loaded Hydrogel Reduce Bacterial Colonization and Biofilm Formation in Vitro?

BACKGROUND Implant-related infections represent one of the most severe complications in orthopaedics. A fast-resorbable, antibacterial-loaded hydrogel may reduce or prevent bacterial colonization and biofilm formation of implanted biomaterials. QUESTIONS/PURPOSES We asked: (1) Is a fast-resorbable hydrogel able to deliver antibacterial compounds in vitro? (2) Can a hydrogel (alone or antibact...

متن کامل

Antibiotic Bone Cement Cannot Reduce Deep Infection After Primary Total Knee Arthroplasty.

Deep infection following total knee arthroplasty is a catastrophic complication. Recently, antibiotic-loaded bone cement has been applied to prevent deep infection after total joint arthroplasty. However, there is still controversy about the prophylactic effect of antibiotic-loaded bone cement after primary total knee arthroplasty. This study reviewed 2293 patients who underwent primary total k...

متن کامل

Sonication of antibiotic-loaded cement spacers in a two-stage revision protocol for infected joint arthroplasty

BACKGROUND Culturing of the sonication fluid of removed implants has proven to be more sensitive than conventional periprosthetic tissue culture for the microbiological diagnosis of prosthetic joint infection. Since bacteria surviving on antibiotic-loaded cement spacers used in a two-stage exchange protocol for infected arthroplasties may cause the persistence of infection, in this study we ask...

متن کامل

A Mouse Model of Post-Arthroplasty Staphylococcus aureus Joint Infection to Evaluate In Vivo the Efficacy of Antimicrobial Implant Coatings

BACKGROUND Post-arthroplasty infections represent a devastating complication of total joint replacement surgery, resulting in multiple reoperations, prolonged antibiotic use, extended disability and worse clinical outcomes. As the number of arthroplasties in the U.S. will exceed 3.8 million surgeries per year by 2030, the number of post-arthroplasty infections is projected to increase to over 2...