Impact of polymer formulations on neointimal proliferation after zotarolimus-eluting stent with different polymers: insights from the RESOLUTE trial.
نویسندگان
چکیده
BACKGROUND Polymer formulation may affect the efficacy of drug-eluting stents. Resolute, Endeavor, and ZoMaxx are zotarolimus-eluting stents with different stent platforms and different polymer coatings and have been tested in clinical trials. The aim of this analysis was to compare the efficacy of zotarolimus-eluting stents with different polymers. METHODS AND RESULTS Data were obtained from the first-in man trial or first randomized trials of each stent, The Clinical RESpOnse EvaLUation of the MedTronic Endeavor CR ABT-578 Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions (RESOLUTE), Randomized Controlled Trial to Evaluate the Safety and Efficacy of the Medtronic AVE ABT-578 Eluting Driver Coronary Stent in De Novo Native Coronary Artery Lesions (ENDEAVOR II), and ZoMaxx I trials. Follow-up intravascular ultrasound analyses (8 to 9 months of follow-up) were possible in 353 patients (Resolute: 88, Endeavor: 98, ZoMaxx: 82, Driver: 85). Volume index (volume/stent length) was obtained for vessel, stent, lumen, peristent plaque, and neointima. Cross-sectional narrowing was defined as neointimal area divided by stent area (%). Neointima-free frame ratio was calculated as the number of frames without intravascular ultrasound-detectable neointima divided by the total number of frames within the stent. At baseline, vessel, lumen, and peristent plaque volume index were not significantly different among the 4 stent groups. At follow-up, percent neointimal obstruction was significantly lower in Resolute compared with Endeavor, ZoMaxx, and Driver (Resolute: 3.7±4.0, Endeavor: 17.5±10.1, ZoMaxx: 14.6±8.1, Driver: 29.4±17.2%; P<0.001). Greater maximum cross-sectional narrowing and higher neointima-free frame ratio, suggesting less neointimal coverage, were observed in Resolute compared with other stent groups. Multiple regression analysis confirmed that the biodurable polymer used in Resolute independently correlated with neointimal suppression among 3 zotarolimus-eluting stents. CONCLUSIONS The different polymer formulations significantly affect the relative amount of neointima for zotarolimus-eluting stents. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT00248079.
منابع مشابه
Impact of Polymer Formulations on Neointimal Proliferation After Zotarolimus-Eluting Stent With Different Polymers
Background—Polymer formulation may affect the efficacy of drug-eluting stents. Resolute, Endeavor, and ZoMaxx are zotarolimus-eluting stents with different stent platforms and different polymer coatings and have been tested in clinical trials. The aim of this analysis was to compare the efficacy of zotarolimus-eluting stents with different polymers. Methods and Results—Data were obtained from t...
متن کاملAngiographic and clinical comparison of novel Orsiro Hybrid sirolimus-eluting stents and Resolute Integrity zotarolimus-eluting stents in all-comers with coronary artery disease (ORIENT trial): study protocol for a randomized controlled trial
BACKGROUND The Orsiro Hybrid sirolimus-eluting stent is a newly developed third-generation drug-eluting stent, featuring a unique dual-polymer mix. An active bioabsorbable polymer delivers the anti-proliferative drug, sirolimus, via controlled release, while a passive biocompatible polymeric coating shields the metallic strut from surrounding tissue, preventing interaction. To date, the Orsiro ...
متن کاملTissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent vs. a fluoropolymer-coated everolimus-eluting stent at 13-month follow-up: an optical coherence tomography substudy from the RESOLUTE All Comers trial
AIMS To compare the tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent (ZES) vs. a fluoropolymer-coated everolimus-eluting stent (EES) at 13 months, using optical coherence tomography (OCT) in an 'all-comers' population of patients, in order to clarify the mechanism of eventual differences in the biocompatibility and thrombogenicity of the devices. METHODS AND RESULTS P...
متن کاملEvaluation in 3 months duration of neointimal coverage after zotarolimus-eluting stent implantation by optical coherence tomography: the ENDEAVOR OCT trial.
OBJECTIVES We performed this study to investigate the vascular response in early period after zotarolimus-eluting stent (ZES) (Endeavor Sprint, Medtronic CardioVascular, Minneapolis, Minnesota) implantation. BACKGROUND The ZES has different characteristics, with biocompatible polymer and rapid drug-elution, compared with the first-generation drug-eluting stents (DES). METHODS The ENDEAVOR O...
متن کاملSafety and efficacy outcomes of first and second generation durable polymer drug eluting stents and biodegradable polymer biolimus eluting stents in clinical practice: comprehensive network meta-analysis
OBJECTIVES To investigate the safety and efficacy of durable polymer drug eluting stents (DES) and biodegradable polymer biolimus eluting stents (biolimus-ES). DESIGN Network meta-analysis of randomised controlled trials. DATA SOURCES AND STUDY SELECTION Medline, Google Scholar, Embase, and Cochrane Central Register of Controlled Trials (CENTRAL) database search for randomised controlled tr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Cardiovascular interventions
دوره 4 3 شماره
صفحات -
تاریخ انتشار 2011