Normal and Prosthetic Atrioventricular Valve Motion in Atrial

نویسنده

  • Donald C. Harrison
چکیده

In order to correlate the electrical and mechanical events occurring in atrial flutter, three patients have been studied using the standard electrocardiogram, a computerprocessed vectorcardiogram, and reflected ultrasound recordings of valvular motion. Anterior motion of the mitral valve leaflet occurs in the region of the nadir of the atrial flutter wave in lead II of the electrocardiogram. In one patient in whom it was possible to obtain a tricuspid leaflet echocardiogram, anterior motion was also initiated close to the nadir of the flutter wave. The probable sequence of electrical and mechanical events in atrial flutter is discussed. In one patient with a prosthetic mitral valve, correlation of diastolic clicking sounds with respect to the poppet echocardiogram provided some insight into irregularities in timing of previously reported flutter sounds.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Normal and prosthetic atrioventricular valve motion in atrial flutter. Correlation of ultrasound, vectrocardiographic, and phonocardiographic findings.

In order to correlate the electrical and mechanical events occurring in atrial flutter, three patients have been studied using the standard electrocardiogram, a computerprocessed vectorcardiogram, and reflected ultrasound recordings of valvular motion. Anterior motion of the mitral valve leaflet occurs in the region of the nadir of the atrial flutter wave in lead II of the electrocardiogram. In...

متن کامل

Motion of the tricuspid valve annulus in anesthetized intact dogs.

Phasic variations in the size, position, and geometry of the tricuspid valve annulus during the cardiac cycle were studied in five normal anethetized dogs 2-6 weeks after 8-11 lead beads had been sutured on the endocardial surface of the valve ring during cardiopulmonary bypass. Field-by-field measurements from biplane videoangiograms were used to assess changes in valve ring size and shape dur...

متن کامل

Aortic root and left atrial wall motion. An echocardiographic study.

The echocardiographically recorded movement of the aortic root was studied by analysing the relation between posterior aortic wall motion and other intracardiac events. The systolic anterior movement of the aortic root continued beyond aortic valve closure and in cases with mitral regurgitation began significantly earlier than in normal subjects. The diastolic rapid posterior movement began aft...

متن کامل

Successful Use of Two Thrombolytic Drugs in Prosthetic Mitral and Aortic Valve Thrombosis

Introduction: Prosthetic valve thrombosis is a rare and severe complication of valve replacement, most often encountered with a mechanical prosthesis. The significant morbidity and mortality associated with this condition warrant rapid diagnostic evaluation. Although surgery is the first-line therapy in symptomatic obstructive mechanical valve thrombosis, thrombolytic therapy has been used as a...

متن کامل

Echocardiographic pattern of right ventricular diastolic volume overload in children.

SUMIMARY Echocardiograms were performed on 20 children who were 1-14 years old. Ten children hald secundum atrial septal defects (ASD 2°); four had partial and two had complete atrioventricular canal defects (AVC); and three had partial and one had total ainomalous pulmonary venous connection (APVC). Twenty-eight normal children were also examined. Echocardiograms of nine patients with ASD 2° r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005