Radiotherapy plays an important role in the treatment of early-stage Hodgkin lymphoma, but late toxicities such as cardiovascular disease and second malignancy are a major concern. Our aim was to evaluate the potential of deep inspiration breath-hold (DIBH) and intensity-modulated radiotherapy (IMRT) to reduce cardiac dose from mediastinal radiotherapy. A 24 year-old male with early-stage bulky mediastinal Hodgkin lymphoma received involved-site radiotherapy as part of a combined modality programme. Simulation was performed in free breathing (FB) and DIBH. The target and organs at risk were contoured on both datasets. Free breathing-3D conformal (FB-3DCRT), DIBH-3DCRT, FB-IMRT and DIBH-IMRT were compared with respect to target coverage and doses to organs at risk. A 'butterfly' IMRT technique was used to minimise the low-dose bath. In our patient, both DIBH (regardless of mode of delivery) and IMRT (in both FB and DIBH) achieved reductions in mean heart dose. DIBH improved all lung parameters. IMRT reduced high dose (V20), but increased low dose (V5) to lung. DIBH-IMRT was chosen for treatment delivery. Advanced radiotherapy techniques have the potential to further optimise the therapeutic ratio in patients with mediastinal lymphoma. Benefits should be assessed on an individualised basis.
منابع مشابه
Life years lost attributable to late effects after radiotherapy for early stage Hodgkin lymphoma: The impact of proton therapy and/or deep inspiration breath hold
BACKGROUND AND PURPOSE Due to the long life expectancy after treatment, the risk of late effects after radiotherapy (RT) is of particular importance for patients with Hodgkin lymphoma (HL). Both deep inspiration breath hold (DIBH) and proton therapy have been shown to reduce the dose to normal tissues for mediastinal HL, but the impact of these techniques in combination is unknown. The purpose ...
متن کاملA Comparative Study of 3-D Conformal Radiotherapy Treatment Plans with and Without Deep Inspiration Breath-Hold Technique for Left-Sided Breast Cancer
Introduction: The rate of cardiac diseases have increased among patients who underwent radiotherapy for left-sided breast cancer. The study’s aim was evaluate the dose to organs at risk in free-breathing 3-dimensional conformal (FB-3DCRT) against 3-dimensional conformal deep inspiration breath-hold (3DCRT-DIBH) in patients with left-sided breast cancer. Ma...
متن کاملRadiation-induced second malignancies after involved-node radiotherapy with deep-inspiration breath-hold technique for early stage Hodgkin Lymphoma: a dosimetric study
BACKGROUND To estimate the risk of radiation induced second cancers after radiotherapy using deep-inspiration breath-hold (DI) technique with three-dimensional conformal (3DCRT) and volumetric arc therapy (VMAT) for patients with Hodgkin's lymphoma (HL). METHODS Early-stage HL with mediastinal and supraclavicular involvement was studied using an Alderson phantom. A whole body CT was performed...
متن کاملDosimetric advantages of a “butterfly” technique for intensity-modulated radiation therapy for young female patients with mediastinal Hodgkin’s lymphoma
PURPOSE High cure rates for Hodgkin's lymphoma must be balanced with long-term treatment-related toxicity. Here we report an intensity-modulated radiation therapy (IMRT) technique that achieves adequate target coverage for mediastinal disease while minimizing high- and low-dose exposure of critical organs. METHODS AND MATERIALS Treatment plans for IMRT and conventional anteroposterior-postero...
متن کاملNoncoplanar intensity‐modulated radiation therapy for young female patients with mediastinal lymphoma
The purpose of this study is to apply noncoplanar intensity-modulated radiation therapy (Nonco_IMRT) to young female patients with mediastinal lymphoma. Nonco_IMRT was evaluated through a planning comparison study with coplanar IMRT (Co_IMRT) and conventional anteroposterior and posteroanterior fields (AP-PA) plans. Co_IMRT was performed with five equally spaced beams starting from a gantry ang...