Prognostic utility of 90Y radioembolization dosimetry based on fusion 99mTc-macroaggregated albumin-99mTc-sulfur colloid SPECT.

نویسندگان

  • Marnix G E H Lam
  • Michael L Goris
  • Andrei H Iagaru
  • Erik S Mittra
  • John D Louie
  • Daniel Y Sze
چکیده

UNLABELLED Planning hepatic (90)Y radioembolization activity requires balancing toxicity with efficacy. We developed a dual-tracer SPECT fusion imaging protocol that merges data on radioactivity distribution with physiologic liver mapping. METHODS Twenty-five patients with colorectal carcinoma and bilobar liver metastases received whole-liver radioembolization with resin microspheres prescribed as per convention (mean administered activity, 1.69 GBq). As part of standard treatment planning, all patients underwent SPECT imaging after intraarterial injection of 37 MBq of (99m)Tc-macroaggregated albumin ((99m)Tc-MAA) to simulate subsequent (90)Y distribution. Immediately afterward, patients received 185 MBq of labeled sulfur colloid ((99m)Tc-SC) intravenously as a biomarker for normal hepatic reticuloendothelial function and SPECT was repeated. The SPECT images were coregistered and fused. A region-based method was used to predict the (90)Y radiation absorbed dose to functional liver tissue (DFL) by calculation of (99m)Tc-MAA activity in regions with (99m)Tc-SC uptake. Similarly, the absorbed dose to tumor (DT) was predicted by calculation of (99m)Tc-MAA activity in voxels without (99m)Tc-SC uptake. Laboratory data and radiographic response were measured for 3 mo, and the survival of patients was recorded. SPECT-based DT and DFL were correlated with parameters of toxicity and efficacy. RESULTS Toxicity, as measured by increase in serum liver enzymes, correlated significantly with SPECT-based calculation of DFL at all time points (P < 0.05) (mean DFL, 27.9 Gy). Broad biochemical toxicity (>50% increase in all liver enzymes) occurred at a DFL of 24.5 Gy and above. In addition, in uni- and multivariate analysis, SPECT-based calculation of DT (mean DT, 44.2 Gy) correlated with radiographic response (P < 0.001), decrease in serum carcinoembryonic antigen (P < 0.05), and overall survival (P < 0.01). The cutoff value of DT for prediction of 1-y survival was 55 Gy (area under the receiver-operating-characteristic curve = 0.86; P < 0.01). Patients who received a DT of more than 55 Gy had a median survival of 32.8 mo, compared with 7.2 mo in patients who received less (P < 0.05). CONCLUSION Dual-tracer (99m)Tc-MAA-(99m)Tc-SC fusion SPECT offers a physiology-based imaging tool with significant prognostic power that may lead to improved personalized activity planning.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sze Microspheres : Known Proof of Effectiveness Y - Loaded 90 Based Dosimetry for Liver Cancer Treated Using −

1. Lam MGEH, Goris ML, Iagaru AH, Mittra ES, Louie JD, Sze DY. Prognostic utility of 90Y radioembolization dosimetry based on fusion 99mTc-macroaggregated albumin–99mTc-sulfur colloid SPECT. J Nucl Med. 2013;54:2055–2061. 2. Garin E, Lenoir L, Rolland Y, et al. 99mTc-MAA SPECT/CT based dosimetry accurately predicts tumour response and survival in HCC patients treated with 90Y-loaded glass micro...

متن کامل

Post-radioembolization yttrium-90 PET/CT - part 2: dose-response and tumor predictive dosimetry for resin microspheres

BACKGROUND Coincidence imaging of low-abundance yttrium-90 (90Y) internal pair production by positron emission tomography with integrated computed tomography (PET/CT) achieves high-resolution imaging of post-radioembolization microsphere biodistribution. Part 2 analyzes tumor and non-target tissue dose-response by 90Y PET quantification and evaluates the accuracy of tumor 99mTc macroaggregated ...

متن کامل

Massive hepatomegaly in 99mTc-octreotide scintigraphy: The value of 99mTc-sulfur colloid scan

99mTc-octreotide scintigraphy, performed during the following up a 58-year old man with neuroendocrine tumor demonstrated massive hepatomegaly demonstrating multiple areas of increased and decreased uptake. Due to severe hepatomegaly concurrence of any other abdominal soft tissue lesions could not be excluded. A 99mTc-sulfur colloid scan was done and thoroughly compared wi...

متن کامل

Post-radioembolization yttrium-90 PET/CT - part 1: diagnostic reporting

BACKGROUND Yttrium-90 (90Y) positron emission tomography with integrated computed tomography (PET/CT) represents a technological leap from 90Y bremsstrahlung single-photon emission computed tomography with integrated computed tomography (SPECT/CT) by coincidence imaging of low abundance internal pair production. Encouraged by favorable early experiences, we implemented post-radioembolization 90...

متن کامل

Quantitative Evaluation of Scintillation Camera Imaging Characteristics of Isotopes Used in Liver Radioembolization

BACKGROUND Scintillation camera imaging is used for treatment planning and post-treatment dosimetry in liver radioembolization (RE). In yttrium-90 (90Y) RE, scintigraphic images of technetium-99m (99mTc) are used for treatment planning, while 90Y Bremsstrahlung images are used for post-treatment dosimetry. In holmium-166 (166Ho) RE, scintigraphic images of 166Ho can be used for both treatment p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 54 12  شماره 

صفحات  -

تاریخ انتشار 2013