Effect of bipolar electrode spacing on phrenic nerve stimulation and left ventricular pacing thresholds: an acute canine study.
نویسندگان
چکیده
BACKGROUND Phrenic nerve stimulation (PNS) is a common complication of cardiac resynchronization therapy when left ventricular (LV) pacing occurs via a coronary vein. The purpose of this study was to evaluate the effects of bipolar electrode spacing on PNS and LV pacing thresholds. METHODS AND RESULTS Electrophysiology catheters with standard (2 mm-5 mm-2 mm) or modified (1 mm-5 mm-1 mm) interelectrode spacing was, respectively, inserted in a posterior/lateral cardiac vein in a randomized order in 6 anesthetized dogs via jugular access. The phrenic nerve was dissected via a left minithoracotomy and repositioned over the vein as close as possible to one of the electrodes. The presence of PNS was verified (ie, PNS threshold <2 V at 0.5 ms in unipolar configuration). Bipolar pacing was delivered using the electrode closest to the phrenic nerve as the cathode, and multiple bipolar electrode spacing configurations were tested. During bipolar pacing, PNS threshold increased as bipolar electrode spacing was reduced (P<0.05), whereas LV pacing thresholds did not change significantly (P>0.05). Compared with a standard bipolar electrode spacing of 20 mm for LV leads, 1 and 2 mm bipolar electrode spacing resulted in a PNS threshold increase of 5.5±2.2 V (P=0.003) and 2.8±1.7 V (P<0.001), respectively. Similarly, PNS threshold increased by 6.5±3.7 V with 1 mm and by 3.8±1.9 V with 2 mm bipolar pacing (both P<0.001), compared with unipolar pacing. CONCLUSIONS This study suggests that reducing LV bipolar electrode spacing from the standard 20 mm to 1 or 2 mm may significantly increase the PNS threshold without compromising LV pacing thresholds.
منابع مشابه
Abrupt disruption of remote monitoring transmission as an indicator of safe backup mode
963–9. 21. Rinaldi CA, Burri H, Thibault B, Curnis A, Rao A, Gras D et al. A review of multisite pacing to achieve cardiac resynchronization therapy. Europace 2015;17:7–17. 22. Biffi M, Foerster L, Eastman W, Eggen M, Grenz NA, Sommer J et al. Effect of bipolar electrode spacing on phrenic nerve stimulation and left ventricular pacing thresholds an acute canine study. Circ Arrhythmia Electrophy...
متن کاملQuadripolar Leads in Cardiac€Resynchronization Therapy
Ma Despite the benefit of cardiac resynchronization therapy (CRT) in patients with heart failure and conduction delay, a considerable number of patients do not respond substantially. Left ventricular lead position is an important factor in response, restricted by the patient’s specific anatomy and local pathophysiology. Quadripolar leads could enhance response to CRT, offering 4 pacing location...
متن کاملCardiac Resynchronization Therapy - How to Overcome High Left Ventricular Pacing Thresholds and Avoid Phrenic Nerve Stimulation
High pacing thresholds and phrenic nerve stimulation (PNS) are not uncommon in contemporary cardiac resynchronization therapy (CRT) systems, based on our own experience as well as on other series. Whereas some cases may be resolved by programming, other cases necessitate reoperations or abandonment of the left ventricular (LV) lead. Approaches to avoid and to manage these two problems are revie...
متن کاملQuadripolar Left Ventricular Lead in a Patient with CRT-D Does Not Overcome Phrenic Nerve Stimulation
Effective cardiac resynchronization therapy (CRT) requires an accurate atrio-biventricular pacing system. The innovative Quartet lead is a quadripolar, over-the-wire left ventricular lead with four electrodes and has recently been designed to provide more options and greater control in pacing vector selection. A lead with multiple pacing electrodes is a potential alternative to physical adjustm...
متن کاملAcute and chronic performance evaluation of a novel epicardial pacing lead placed by percutaneous subxiphoid approach in a canine model.
BACKGROUND Endovascularly implanted leads risk vascular injury and endocarditis, and can be difficult to locate in desired positions for LV pacing. We evaluated the acute and long-term stability, electric performance and histopathology of a percutaneously placed intrapericardial lead (IPL). METHODS AND RESULTS Twelve adult mongrel dogs underwent defibrillator implants incorporating IPLs. Succ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Arrhythmia and electrophysiology
دوره 5 4 شماره
صفحات -
تاریخ انتشار 2012